Ground for 400 amp service

I know that the required size of the grounding electrode for a typical 200 Amp service is a #4 solid copper. Now, we are planning on a 400 Amp service and I'm not sure what size PG&E will be running in the 3" PVC service lateral conduit but the length is approx. 300' so I'm assuming a pretty large set of service conductors.

Ground for 400 amp service. Ground Wire Size Calculator. The Ground Conductor Size Calculator will calculate the proper ground conductor size for grounding raceways and equipment based on …

For the wire sizing do I need to have conductors large enough to carry 1200 amps on each leg or conductors to carry 400 amps per leg ? Thanks . Jraef Moderator, OTD. Staff member. Location San Francisco Bay Area, CA ... Wire size for a 480V 3PH /1200 Amp Service Wire size for a 480V 3PH /1200 Amp Service Thanks for the replys. …

Where equipment grounding conductors are installed with paralleled feeder conductors, the requirements in 310.4 have mandatory application. To develop an understanding of the requirements in 310.4 and 250.122 (F), a brief review of the rules in 300.3 (B) and 250.134 (B) is in order. The requirements in these sections call for all conductors of ...200 amp meter base wiring diagram400 amp service with two 200 amp disconnects...is my grounding across How to wire a 400 amp 480/277 panel correctlyWhat wire is needed for a 400 amp service between the mast and the.The term 400 amp service means the capacity of your home electric service. The capacity is actually measured by the amp. This also means that the current flows through the wire. So, in simple terms, the whole 400 amperage current flows through the wire and its maintenance is the 400 amp service. Making an upgrade on your …250.50 Grounding Electrode System. All grounding electrodes as described in 250.52(A)(1) through (A)(7) that are present at each building or structure served shall be bonded together to form the grounding electrode system. Where none of these grounding electrodes exist, one or more of the grounding electrodes specified in 250.52(A)(4) throughfigure 53: 100/200 amp meter socket, underground service ----- 94 figure 54: power leg connection on 3 phase, 4 wire delta connected systems ----- 95 figure 55: 400 amp to 1200 amp ct metering, underground service ----- 99Meter amp socket milbank 200 wiring diagram ground 400 base two double disconnects service electrical electric main load wps revisedConfiguring 400 amp …In this article, we will delve into the factors you need to consider when determining the size of the ground wire for a 400 amp service. By following these guidelines, you can ensure that your electrical system is safe and compliant with regulations. ... Then, we will discuss specific factors that come into play when dealing with a 400 amp ...

What Is The Ground Wire Size For 400-Amp Service? The correct ground wire size to use for a 400-amp service typically depends on the gauge cable used for the panel. Assuming that the service panel uses a 700 kcmil copper wire, a ground wire that can handle 5,000 amps should suffice.3-Pole, 4-Wire, 240-Volt, 400-Amp fusible safety switch with neutral. Quick-make, quick-break operating mechanism that ensures positive operation. Generous wiring gutters that meet or exceed NEC wire-bending space requirements. Highly visible red handle grip. Padlocking provisions to lock cover closed or to lock handle positonIf you apply the NEC 80% rule, 250 kcmil wire can handle up to 204 amps. That's why it is considered a 200 amp wire. Basically, we are trying to answer what ground wire do you need for 200 amp service. If you consult the copper ground wire size chart above, you can see that you will need a 2 AWG copper ground wire to adequately ground a 250 ...Working out a concept for a manufactured product but not sure how to build it? QoQer is helping manufacturing startups get off the ground. Working out a concept for a manufactured ...But in retrospect when there was individual standalone service switches for example a 400 amp service switch that was part of a 1000kva installation the advisory board required 5 Ft. clearance in front of it. ... Should the grounding conductor in a 4000A service switchboard (where 4-1/4"x6" copper is being used to meet 230.42) be based on the ...Apr 19, 2009 · rgsgww Discussion starter. 1543 posts · Joined 2008. #1 · Apr 19, 2009 (Edited) I currently have a 400 amp service with two 200 amp service panels, the ground is a water pipe connected with what looks like 4 awg stranded. There is one rod with 6 awg solid. If I were to update the grounding system, wouldn't I need to sink rods for each panel?

At the big 400 amperes current, the voltage drop is less significant. To help you out, we have prepared 2 charts for running a 0-500 feet wire for 400 amp service at 120V and 220V voltages. The 1st one accounts for a 3% allowable voltage drop, while the 2nd one accounts for a less rigorous 10% allowable voltage drop.Seems counterintuitive to reference a table dealing with bonding a raceway vs a system ground. unless you guys have a local rule it's 6 for your system ground. doesn't matter if it's a 100 amp single phase or 1200 amp 3 phase service. it USED to be different (i think 2 code books ago) Ontario, Canada 10-114 CEC states minimum #6AWG Copper but ...That said, a 400-amp service will give you a lot more flexibility. You can have two good sized 200 amp panels in different parts of the house, Each panel will hold around 40 breakers. This allows more runs, and shorter runs from the panels to the outlets and other devices. Shorter runs mean less voltage drop that means less heat generated in ...Anyways, we decided to put up a 400 amp service because we know how this customer works. The question came up when it came to bonding the gas and water lines. Because of our service feeder sizing 3/0 in 2 parallels. I was questioned on the sizing of my water and gas bond because I ran 1/0 copper ground to the lines.Without a proper ground, electrical shock and even fires can occur. Now, back to the question at hand. The size of the ground wire for a 100 amp service depends on a number of factors, including the type of wire being used, the distance between the electrical panel and the main service entrance, and the gauge of the wire.. Generally, a …

58 open.

Oct 1, 2023 · What Is The Ground Wire Size For 400-Amp Service? The correct ground wire size to use for a 400-amp service typically depends on the gauge cable used for the panel. Assuming that the service panel uses a 700 kcmil copper wire, a ground wire that can handle 5,000 amps should suffice.Microsoft's reimagined Teams promises double the performance, reduced memory usage and improved user experience. Teams, Microsoft’s Slack rival, has always had a bit of a reputatio...The 400-amp service is fed with (2) parallel runs of 3/0 copper service conductors, and (2) paralleled #2copper for the grounded conductor. the only GEC i have found is #2 that goes to a single ground rod outside see picture #4, and another #2 that goes to a water pipe. The plumbers got a hold of the water pipe since the main line broke outside.Underground Service Rev. 1.10.20 GROUNDING: 1. National Electric Code approved grounding required. For 200amp service, bond enclosure with #4 bare copper. For 400amp service, bond enclosure with #2 bare copper. 2. Ground wire between meter enclosure ground lug and ground rod shall be continuous with no splices. CONSTRUCTION HOTLINE 1.866.992.6619

For a 400 amp service, the minimum recommended cable size is 2/0 AWG copper or 4/0 AWG aluminum. However, depending on the length of the cable run and the level of current flowing through the cables. Larger cable sizes may be necessary to meet voltage drop requirements and ensure safe and efficient operation of the electrical system.But let’s first look at what constitutes an equipment grounding conductor (EGC) and how it differs from the oft-misunderstood grounding electrode conductor (GEC) that connects noncurrent-carrying metal parts of the electrical service to the electrode buried in the earth. EGCs VS. GECs. Equipment Grounding Conductor (EGC): Table …CUSTOMER INSTALLATIONSTANDARDS FOR ELECTRIC SERVICE September 4, 2018 A transition period will exist in which installations may be approved and connected as long as they meet either the 20 13 or the 2018 editions.If the sub panel needs to be located at 150 feet distance from the main panel, then the most suitable 50 amp sub panel wire size would be 4 AWG copper or 3 AWG aluminum, but a 6 AWG copper wire size for 50 amps may still work.; If the sub panel needs to power appliances and power tools 200 feet away from the service panel, it's also advisable to use 4 AWG copper or 3 AWG aluminumAllowable ampacity of 3/0 copper wire is 225 Amp, while the allowable ampacity of 4/0 aluminum wire is 205 Amp. 2/0 AWG copper wire is not completely out of the question, but its ampacity is 195 Amp-200 Amp, which will put it at a maximum load, so using 3/0 AWG copper is a better option. For grounding conductors, the minimum size …400 amps * .83= 332 amps conductor- which is necessary for the 400 amp service on a residence. You would have to de-rate 80% because of the number of conductors in a conduit. 4/0 aluminum is good for 205 amps at 90C--- 205 * 2= 410.... 80% of 410= 328 which is what Wayne had.I was hoping to get some advise for a service upgrade that I plan to do soon. I need to upgrade from a 200 amp to a 400 amp service. I plan to install the POCO 400 amp meter base and then connect 2- 200 amp disconnects in parrallel. My question is the termination of the GEC. There is a lug in...Total Time: 15 mins. The main electrical service delivered to your house from the electrical utility company has a total available capacity, measured in amps, or amperes. Most homes have an electrical service of between 100 to 200 amps. Amperage is a measurement of the volume of electricity flowing through wires, and this measurement can vary ...I disagree with the need for 1/0 for the grounding electrode conductor. This is one of those strange anomalies in the code. If you have a 400 amp meter main then 1/0 is needed for the grounding electrode conductor however, if you have 2- 200 amp disconnects with 3/0 copper to each then a #2 is all that is required to the ground electrode.

Sep 30, 2004. #7. Re: 400 amp service Since each of these panels is service equipment, each has a "grounded service conductor" and also has the grounded/grounding bus bonded to the service enclosure. Per 250.53 (D) (2), you can bond at any of these locations: "The supplemental electrode shall be permitted to be bonded to the grounding electrode ...

How to ground 400 amp service with 2 200 amp panels one on disconnect switch tkrussell Posts: 9,659, Reputation: 725. Uber Member : Oct 21, 2007, 04:58 AM At the main disconnect, is where the incoming Line neutral, the two neutrals going to the two panels, the two equipment grounding conductors, and the grounding electrode conductor all connect ...Apr 26, 2022. #4. Our poco would run a 4/0 triplex for a 400 amp underground service, until they got so many complaints about voltage drop. Apparently they got sued, now they reduced the max length of the secondary, and run 350. I built a 1200 amp service, and they wanted to drop 3-sets of 4/0 to it!The ordinary code of wire to use for a 200 amps service panel is #2/0 copper wire that needs to have a conduit of 2 inches. The electric code of your country may also set the bar for utmost safety. For aluminum or copper-clad wire, there shall be a wire with a gauge of #4/0 AWG. The MCM rating would be 211.60 kcmil.Amp 400 panel meter installed Meter amp 200 base 400 service replacing electrical subpanel Meter base amp 200 wiring diagram installation disconnect 200a …400-amp services are rare. You will be hard-pressed to find a 400A service in a home because most residential properties do not require that kind of power. The amp service is more likely to appear in a large house with massive, heavy-duty appliances like pools.Three hinges are required for doors from 36" through 72" high. Four hinges are required for doors over 72" high. Hinge pins must be stainless steel and 5/16" diameter minimum. Switch compartments must have a window built with safety glass or equivalent for easy viewing of switch status by a person of normal height.In this case, a 100 amp sub panel would require a minimum of 4 AWG copper or 2 AWG aluminum ground wire. However, it's important to also consider the type of wire being used for the branch circuit and the distance between the main panel and sub panel. Heavy loads and longer distances may require a larger ground wire to ensure proper grounding ...Overview. The Square D 400 Amp 30-Space 40-Circuit Combination Meter Socket and Dual Main Breaker Load Center is suitable for use as a combination service entrance device (CSED) and is a ring-type unit. It is suitable for underground service applications. Accommodates plug-on secondary surge arrestor, and features a plug-in design for easy ...

Upland aeries.

Griswold 14.

rgsgww Discussion starter. 1543 posts · Joined 2008. #1 · Apr 19, 2009 (Edited) I currently have a 400 amp service with two 200 amp service panels, the ground is a water pipe connected with what looks like 4 awg stranded. There is one rod with 6 awg solid. If I were to update the grounding system, wouldn't I need to sink rods for each panel?Going to upgrade to a 200 amp service. Going to run from pole transformer to house breaker panel 150 feet underground. 120 volts. What cable size and conduit is required. On 2015-11-09 by (mod) - wiring size information for 200 amp underground service with a 450 foot run. Sure Mike You didn't specify voltage but I assume you meant 240V.what cable do I need for a 400 amp service 650 ft run and what transformer. On 2020-08-26 y Mike Lange . I am looking for underground wire size needed to run 1200 feet .. I would like a 30 amp 240 volt service . On 2020-08-20 by frank . what size underground wire do I use for 200 amp service for generator that is 200 ft away from the service meter?Ground an outlet: $25 to $100: ... Now, 200-amp service is common for most homes, and 400-amp service is often installed for very large homes with many electric appliances, such as swimming pool heaters and radiant floor systems. Rewire a House . The cost of rewiring a house ranges from $1,600 to $11,400.400 Amp Standard House Panel, Ring Style, 4 Jaws, 8 Spaces, Single-Phase, 120/240V, 22 kAIC, 8/16 Distribution, Main Breaker Type, UG Service, NEMA 3R - Rainproof Enclosure, Surface Mount, Overhead/Underground Feed, Includes: 200 Amp (BWH200) Main Breaker and Option For Secondary Main Breaker of BW or BWH Type. Branch Circuit Breakers: BR or BRH, Cat #: HP816P400BS, Mfr: EatonThe grounding system design for a 400 amp service generally involves the use of multiple grounding electrodes, such as ground rods or conductive plates, strategically placed around the property. These electrodes are connected to the grounding conductor, which is typically made of copper or aluminum, and runs from the main electrical panel to ...Sep 18, 2023 · The ground wire in a 100 amp service is designed to provide a safe path for electrical current to flow in the event of a fault or short circuit. How do I determine the proper size of ground wire for a 100 amp service? The size of the ground wire for a 100 amp service depends on the type of wiring used and the distance between the electrical ...How to ground 400 amp service with 2 200 amp panels one on disconnect switch tkrussell Posts: 9,659, Reputation: 725. Uber Member : Oct 21, 2007, 04:58 AM At the main disconnect, is where the incoming Line neutral, the two neutrals going to the two panels, the two equipment grounding conductors, and the grounding electrode conductor all connect ...the service disconnecting means shall be installed in bathrooms. tvo 3/0 avg black conductors to main breaker vhite or marked vhite conductor td neutral bus 1/0 bare copper to grounding bus bonding jumper or bonding screv panel on riser rigid or strap 3 inch te metal conduit 400 amp meter base should be 5 ft. to 5-1/2 ft. above ground level to ….

Q: What should my overhead or underground 400 amp or single-phase service look like? A: Please refer to Customer Guide Exhibit 6 for overhead and Customer Guide Exhibit 8 for underground. For stand-alone underground services, refer to Customer Guide Exhibit 12. Q: Do I need to run my underground service lateral up the pole or into a nearby handholewhat cable do I need for a 400 amp service 650 ft run and what transformer. On 2020-08-26 y Mike Lange . I am looking for underground wire size needed to run 1200 feet .. I would like a 30 amp 240 volt service . On 2020-08-20 by frank . what size underground wire do I use for 200 amp service for generator that is 200 ft away from the service meter?For a 400-amp service, you will need a wire size of at least 350 kcmil for copper wires or 600 kcmil for aluminum wires. It’s essential to adhere to the National Electrical Code (NEC) and local regulations, and consult with a qualified electrician to ensure proper installation and safety. 400 amp Service Wire Size Chart:400 amp service 400 amp service Under the 2002 code 250.32 (A)(B)(C) deal with the GEC. In my understanding it is a better installation to establish grounding in the new structure (ufer ground) than to bring the 4th wire over in case nuetral was ever lost.I think you're asking what size does the grounding electrode conductor need be. This is not determined by the size of the service or your breakers. It's determined in 250.66 by the size of your service conductors. 400A service is typically something like 1000 kcmil aluminum which would require a 4/0 Al or 2/0 Cu GEC.Nov 29, 2012. #2. Based on 2008 250.66 (B) Connections to Concrete-Encased Electrodes. Where the grounding electrode conductor is connected to a concrete-encased electrode as permitted in 250.52 (A) (3), that portion of the conductor that is the sole connection to the grounding electrode shall not be required to be larger than 4 AWG copper wire.the utilitys in our area require CT's on 400 amp. I'm not sure if a 400 amp base is available for 3 phase. Normally in a case such as you describe, we would come out of CT cabinet and hit the 2 200 amp panels with 3/0 and # 4 ground. the inspectors and utility in this area want all grounding tied back into the CT cabinet.Conductor Sizing and the National Electrical Code Ground for 400 amp service, For a 400 amp service with aluminum, aim for a 1,000 kcmil wire. And for the ground, a 1 AWG aluminum wire should do the trick. So here’s a quick recap for you: …, Upper Jay, NY. May 7, 2007. #3. millspgh said: I need to give a price on a 400 amp, 3 phase 4 wire service, and I don't want to get burned by the derating issue. I was planning on running 4 500mcms in a 4" pvc pipe, the pipe will be about 100' long above a drop ceiling in a retail area. I know by having 4 current carrying conductors I need to ..., I've never used concrete encased (Ufer) grouding. Is the grounding conductor for a service sized in accordance with NEC Table 250.66 using Ufer method? Service is 6 sets 4" with 4 - 500MCM (Ok, KCMIL) Thanks in advance for your help. Steve, 600, 800, 1200, 480 3 phase temp services have only two ground rods. What size ground rod is needed for a 400 amp service? Two ground rods should be at least 6′ apart. The ground wire should be 1/0 copper with a rod 4 to 6 below grade., Without the 83% rule for dwellings, this would be 335A. For dwellings, it would be 400 (because we cant seem to go above 400 otherwise it would be 404). Because you have two service enclosures, see 250.64 (D) - depending on what method you use, there may be taps that can be smaller than the main GEC., For a 400 amp service with aluminum, aim for a 1,000 kcmil wire. And for the ground, a 1 AWG aluminum wire should do the trick. So here’s a quick recap for you: …, Installing an in-ground basketball goal takes no time compared to the countless hours of use that goal will get. Expert Advice On Improving Your Home Videos Latest View All Guides ..., 400 amp service wire size chart - August Place. Check Details. 200 Amp Service Grounding Diagram. Check Details. 400 Amp Ground Wire Size Chart. Check Details. 20 Amp (Breaker, Ground, Service) Wire Size 12V, 120V, 220V, With the Boeing 737 MAX still grounded worldwide, airlines that operate the aircraft are working to adjust their schedules and operations around the aircraft. Following the decisio..., Goal: I'm installing a 400 Amp service in Washington State through Mason County PUD 3. The AHJ is Washington State L&I. For now, I'm installing what's necessary to power my RV and well pump but I ... One in-ground run 750-750-500 MCM Aluminum XHHW-2 from transformer 170ft to meter, in 4" schedule 40 @ 18.96% fill. Replace 600 MCM meter ..., Re: 400 amp service with 2-200 sub panels As for a better way of grounding. Having main bonding jumper father away from the service panel is not a better system useing 230.40 exception #3 will allow the main bonding jumper to be where it is needed at the house this will allow for a faster operation of breakers in the event of a ground fault since you wont have the long run to the meter disconect., The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). Search Amazon for your Electrical ..., They can be used as 200 amp ground wires, wires for 200 amp breaker, they can be copper or aluminum 200 amp wires. ... 400 KCMIL wire with 355A amperage. ... The 250 KCMIL wire is the perfect size wire for 200 amp service because it has 255A ampacity (a minimum of 250A ampacity requirement is satisfied)., Aug 23, 2007. #1. We have a 3000 amp 208/120 volt service. It starts at the POCO's pad mount transformer then to an outdoor CT enclosure. From there it goes under a slab to a 3000 amp MCB switchboard. It has 8 sets of 4-500 kcmil feeders. We use Table 250.66 which says to use a 1/0 for each service feeder. Since the CT enclosure is before the ..., What size wire for 100 amp service 50 feet away? The size of the wire for a 100-amp service 50 feet away would depend on factors such as the voltage and local electrical codes. Typically, this might require 3/0 or 4/0 copper or aluminum conductors. ... A neutral wire should ideally read close to zero voltage when measured with respect to ground ..., In earlier Codes, all these conductors, as well as the Grounding Electrode Conductor, were selected from Table 250.66. Table 250.102(C)(1) from the 2014 NEC. ... For a service that uses four paralleled 500 kcmil conductors per phase, the minimum size main bonding jumper is 250 kcmil., service conductors must be bonded in accordance with the National Electrical Code. • A water line shall not be the sole means of grounding. 10. When either lightning rods or telephone ground rods are within 6 feet of the service ground, they must be bonded together with #6 stranded copper wire with approved clamps. 11., In the trough, the cables are tapped and feed into a 125 amp main breaker panelboard. This is a temporary service. The 400 amp disconnect feeds a double wide trailer, which is a temporary financial bank. the 125 amp panel feeds a work trailer. 500 mcm feeds the meter and the line side of 400 amp fused disconnect. The 500 mcm stops there., Lets say you have a commercial steel frame building with a metal waterline at least 10 in the ground. On this building will be two services. The first is a 400 amp 3 phase and the second service is a 100 amp 3 phase both are different voltages. The 400 amp service has a grounding electrode..., This is a good goal to shoot for when sizing the conductors for an underground cable. The following are the maximum lengths of cable you can use while still maintaining a 3 percent voltage drop for the given wire size (AWG) and circuit voltage. As an example, for a 120-volt circuit, you can run up to 50 feet of 14 AWG cable without exceeding 3 ..., Do the grounding rods need to be different for a 100 amp service, for 200 amp service, and for a 400 amp service? No, they don’t. All three service panels in a residential setting will need at least 2 ground rods, except in the circumstance described above (the rod has very low resistance). When is a ground rod required?, The 800 amp is a service heavy-up from 400 amp and the new service is relocating from one side of the house to the other. All 4 200 amp sub-panels will be located close to 260' away from the service disconnects. -feed out of disconnects with 4/0 SER to 200 amp sub-panels 260' away on the other side of house (sucks)., #1. Hello all; Some clarification on the size of the GEC in a service to a residence with 2 150 amp main breaker panels. Is it determined by the size of the …, How Much Does A 800-Amp Service Cost? If you want to install two 400A services, each 400A service could cost you as much as $4,000. On the other hand, you may spend an estimated $750 to $2,000 on each 200A service. 800-Amp Service Installation Cost. You may spend $10,000 or more depending on the kind of setup you have in mind., First of all, the city will besupplying a 400 amp service. The service equipment will be located away from the house, approx 50 ft. From there the wires feeding any panels within the house will have a 3 inch schedule 80 PVC available as a raceway. The PVC will come up on an inside wall in the garage., Residential service panel grounding methods. 1. Ufer ground. UFER is usually used in the new construction when pouring a new footing. The UFER ground is a minimum of #4 rebar, 20 feet long in concrete per (CEC 250.52 (A) (3)) & (NEC 250.52 (A) (3)) or o 20' of minimum 4 AWG bare copper wire. UFER With an access Panel. 2., Common electrical services include 100, 200, 300, and 400 amps. You need 1¼ inch conduit for 100 amps, 2 inches for 200 amps, 2.5 inches for 300 amps, and 3 inches for 400 amps. The size may differ based on the wire size and the number of wires to put inside the conduit. Multiple factors can affect the conduit size for these electrical services., Oct 21, 2007 · New Home 400 amp service [ 3 Answers ] I brought in 400 amp to my outside meter for my new log home. I had planned to split off 200 to the house and 200 to a future shop. However I don't think 200 will be enough from time to time. One expert I asked said I would be running at 600 AMP requirement. I think he is nuts., E-mail: [email protected] Phone numbers: Appalachian Power Customer Service Phone: 800-982-4237 AEP Ohio Customer Service Phone: 800-672-2231 AEP Texas Customer Service Phone: 877-373-4858 Arkansas Customer Service Phone: 888-216-3523, Sep 6, 2023 · Common electrical services include 100, 200, 300, and 400 amps. You need 1¼ inch conduit for 100 amps, 2 inches for 200 amps, 2.5 inches for 300 amps, and 3 inches for 400 amps. The size may differ based on the wire size and the number of wires to put inside the conduit. Multiple factors can affect the conduit size for these electrical services., We would like to show you a description here but the site won't allow us., For example, the box is 500 amps and the biggest wire is 100 amps. Then having a 500 amp rated ground is pointless because the 100 amp wire will melt long before the ground will. The best ground is an 8-foot copper rod you drive into the ground with a sledge hammer. Then you clamp a braided copper grounding strap to it., For 150 amp, you will need a 1/0-size copper wir e size. For a 200 amp service, you will need a 250 kcmil-gauge copper wire size. For a 400 amp service, you will need a 600 kcmil-gauge copper wire size. For 600 amp, you will need a 1500 kcmil-gauge wir e size. We've got you covered if you want to buy a circuit breaker or a sub-panel.