Alltrax controller fault codes

Product Features. 30-60 VDC (48V models) (60VDC MAX) Control Voltage range: KSI, Throttle Reverse inputs. Control voltage range; Key Switch (KSI), Throttle and Reverse inputs: 24-48 VDC, 60 VDC Max. Reverse Input: 50mA sink max. Standby Current (Powered Up):

Alltrax controller fault codes. 203 posts · Joined 2007. #1 · Feb 21, 2008. I have an Alltrax AXE controller which supports programming through a 9-pin COM port. You can also view amps, volts, and other info about the controller by having it plugged into a computer WHILE using it, or log the data for later viewing. I would like to consider having a computer in the car, that ...

Alltrax FN-DM-K2 User Controls for XCT. The XCT has TWO User inputs called a personality switches. FN-DM-K2 provides dual knobs assigned to Speed and Regen. Interactive Speed+Acceleration or Regen amount and range of regen control for mild street to wild performance. Alltrax Toolkit can set the parameters and range to suite your needs.

Re: Field Open Alarm on Alltrax XCT. If there is no continuity from F1 to F2 there is an internal problem in the motor. You could remove the motor and make sure the studs that connect the F terminals to the field coils have not been twisted and have a good connection to the wire for the field coil.Item #2 400 controller with HD 200 solenoid option. All around Campground & Neighborhood speed controller. 460 peak amp output, 36 or 48 volt operation, choose a 200 amp heavy duty solenoid with a free resistor, & diode. 200 amp HD solenoid is available in 36, 48, or 36/48 volts. Good for moderately bigger tires & rear seats on …BLINK CODES The throttle code blinks on controller power up and alarm codes blink when the alarm happens. All alarms are self clearing so when the alarm event is over, …Program/Upgrade EZGO Controllers (Curtis/Alltrax/Danaher) - Golf. Check Details. Ezgo fault 52 after controller and motor upgrade. Golf ezgo cart front upgrade curtis cable txt shift end much alignment controller rxv controllers weighs alltrax adjustment adjust program .. How to Fix a EZGO Golf Cart that Keeps Beeping (STEPS) - Golf Storage IdeasBalboa Fault Codes Here are the common spa panel messages that you will encounter with your spa panel. The spa panel messages include common diagnostic messages, operational messages, and various other messages such as reminders. ... There may be conditions that exist in which the spa control system will be unable to detect these …Swap the F1 and F2 wires at the controller to correct the operation direction. I don't suppose you could tell us if the controller is flashing a red fault code when you try to go? Or better, connect a laptop and see if the throttle progress bar in the monitor screen is showing 0-100% when the pedal is depressed ( key on / in neutral)DC motor controller for series and permanent magnet motors. ABS + PC510 flame resistant thermal plastic enclosure. All copper heat sinks. Sealed epoxy UL-94-VO / 5VA flame rating (best in industry) Adjustable undervoltage cutback 8-30 VDC. Adjustable overvoltage shutdown 30-60 VDC. Operating Frequency: 18k Hz.

Re: Alltrax Blink Codes - maybe the controller's ok? Quote: Originally Posted by Gigaquad. My controller on my new-to-me cart is supposed to be bad, but I discovered it has blink codes. Cart: Ezgo TXT Series model Model: Altrax SR400 Blink: green green, red red red = which seems to mean "High Throttle Over Range" My thinking is that they didn't ...Repaired Controller + 1st eGator = 3,1 fault code. Running Controller + 1st eGator (again) = 3,1 fault code. Looking into the technical manual for the 1268 controller, they report the 3,1 fault code as: Fault {3,1} MAIN DRIVER OFF - Main contactor driver held high. Possible solutions: 1. Main contactor coil shorted. 2.The throttle code blinks on controller power up and alarm codes blink when the alarm happens. All alarms are self clearing so when the alarm event is over, the controller resumes normal operation, except for the Short Circuit alarm that needs a power off cycle to clear the alarm. throttle codes: 1 Green LED Flash = 0-5k throttlePage 1 6 Green = Taylor-Dunn 6-10.5V Mini-Manual Alltrax reserves the right to repair or replace merchandise at its option at 7 Green = CLUBCAR 5K-3-wire no cost to the customer, except for shipping costs of sending the defect For Golf Car Applications item to Alltrax.; Page 2 BATT puter and the controller which could damage Working on electric …I have a 2017 EZGO TXT 48v cart that was lifted and modified by a company called Trail Hog. I was told the Curtis SepEx Model 1268 Motor Controller was bad so I purchased a new one along with a new solenoid. The new controller and solenoid was installed and it ran good for about a day.Carryall powerdrive on board charger problem. Electric Club CarIn the world of automotive repairs, diagnostic fault codes play a critical role in identifying and resolving issues with vehicles. These codes are generated by the onboard computer...The single LED light on the controller is flashing 5,5 which according to Curtis means MAIN DROPOUT or Main Contactor Open or possible defective contactor. I replaced the solenoid with a heavier duty White Rodgers 48v solenoid hoping that was the problem. It is actually worse and will barely move.

First, connect the voltmeter to the controller and the battery. Connect the voltmeter to the M terminal of the speed controller and the negative terminal of the cart battery. Now push on the cart pedal and check the full battery voltage. As soon as the full voltage is shown, push the entire pedal down.THROTTLE AND BRAKE CODES 31 ALARM CODES 32 CODE DEFINITIONS 33 WARRANTY STATEMENT 35. 4 AC OPERATORS MANUAL ... When installing a new controller, Alltrax recommends the OEM solenoids be replaced with a heavy duty version. ... The fuse must be rated for pack voltage and fault current. 12 AC OPERATORS MANUAL Wiring Controller Min. Wire AWG ...Oct 22, 2020 · How to program Alltrax XCT controller. Alltrax XCT 500 settings. RXV Curtis settings. First, you need to test the power. Connect the negative probe to the M terminal and the positive probe to the B+ terminal. Make use of the accelerator to check the controller. Press the accelerator to see the voltage increase.LED BLINK CODES 19 THROTTLE AND BRAKE CODES 19 ALARM CODES 20 CODE DEFINITIONS 21 WARRANTY STATEMENT 23. 4 AC OPERATORS MANUAL READ AND SAVE THESE INSTRUCTIONS ... the Alltrax controller. • Wear safety glasses. • Because hydrogen can build up due to gassing from the batteries, work in a well ventilated area. ...Alltrax stepped up and designed a NEW product with a NEW warranty, the NCX Non-Programmable controllers. A cost effective solution to replace your aging or damaged stock controller without buying a “rebuilt controller”. Programmable via RS232 comm port using PC or Laptop. Integrated anodized heat-sink with multi bolt pattern for flexibility.

1100 commerce dallas.

ALLTRAX XCT 48500 pds controller with fan from carts unlimited Heavy duty solenoid oredered with controller from carts unlimited July 2018 Trojan T605. 6 volt batteriesAlltrax fault code 5 Electric EZGO. Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV.Just installed an Alltrax controller in a 2016 CC Precedent. Wired correctly. This is not my first install, but is my first Precedent. Powers on but pressing accelerator through the RPM range at about 80% throttle it cuts power and motor ramps down. If I keep the pedal to the floor , the cart lets out a long beep.any instructions provided by Alltrax in verbal or written form. In the event you should need warranty repair, contact Alltrax at (541) 476-3565 to receive warranty service authorization instructions for returning the defective product to Alltrax for evaluation. Products or parts shipped by customer to Alltrax must be sent postage paid andEZ Models: The NPX4834EZ & NPX4844EZ are set up for ITS throttle and have the 5 pin E-Z-GO connection for a true plug and play controller. Standard or Club Car Resistive Throttle Models: The NPX4834 & NPX4844 must be specifically ordered for: 0-5K ohms, 2-wire. 5K-0 ohms, 3-wire. LED STATUS INDICATOR.

Page 1 Solid Green: Controller ready to run Mini-Manual Alltrax reserves the right to repair or replace merchandise at its option at Solid Red: Controller in programming mode no cost to the customer, except for shipping costs of sending the defect...; Page 2 E-Z-Go Diagram Motor Controller NPX4834 & NPX4844 for 1994 and Alltrax, Inc. Our NPX Series motor controllers are designed to older cars ...While the speed controller in your golf cart is designed to last, sometimes unexpected issues can pop up. Learn everything you need to know about troubleshooting and repairing the speed controller in your E-Z-GO golf cart! Charleston: (843) 881-8894. Greenville: (864) 862-7709. Blog;installing an Alltrax Controller. That is the stock controller's programming line. It is not used on Alltrax controllers. Cart runs slow and it doesn't move until the throttle is pushed down about ½ way down. (2001-2006) Rod connecting MCOR and throttle pedal twisted out of shape.Ezgo txt alltrax spm48500ez throttle type troubleshooting: Electric EZGO: Swapping Alltrax AXE 7245 450a for Alltrax SR 72500 500a: Electric EZGO: Troubleshooting Alltrax Controller on DS Series Cart: Electric Club Car: DCX 400 troubleshooting help: Electric EZGO: Troubleshooting an Alltrax NCX300DCS: Electric EZGOControllers. DO NOT Use with Alltrax Controller Heavy Duty — Maximum performance, high speed, maximum torque, pulling loads, hilly terrain or Hunting Buggies. Performance 200 AMP (600amp Inrush) Use with 300 and 400 AMP Controllers Heavy Duty 200 AMP (800A surge) Use with 300 to 500 AMP Controllers Heavy Duty 400 AMP (1000A surge) …Page 2- Small 'pop' near controller. Alltrax error 1 Green, 6 Red Electric EZGOControllers. Alltrax Mini-Manual; Alltrax AXE 4834/4844 & DCX 300 Dimensions; Alltrax SPM Manual; Alltrax SR Manual; Alltrax SR Basic Wiring; Curtis 1253 Manual; ... Gen4 fault codes (short version) Gen4 Simplified Wiring Video Link; VCU for Leaf/ UQM - Manual, Wiring, Troubleshooting; Zilla 1K Spec Sheet;Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV.Over 200,000 Alltrax Electric Motor Controllers have shipped. Each unit reduces thousands of gas emissions each year. Alltrax XCT,NCT,SR, and SPM controllers can be programmed on your bench using a USB printer cable and our free Alltrax Toolkit software. The controller will power up via the USB cable so no external power supplies are needed.

installing an Alltrax Controller. That is the stock controller's programming line. It is not used on Alltrax controllers. Cart runs slow and it doesn't move until the throttle is pushed down about ½ way down. (2001-2006) Rod connecting MCOR and throttle pedal twisted out of shape.

Mar 3, 2019 · Ezgo txt alltrax spm48500ez throttle type troubleshooting: Electric EZGO: Swapping Alltrax AXE 7245 450a for Alltrax SR 72500 500a: Electric EZGO: Troubleshooting Alltrax Controller on DS Series Cart: Electric Club Car: DCX 400 troubleshooting help: Electric EZGO: Troubleshooting an Alltrax NCX300DCS: Electric EZGOfrom Alltrax and it is not necessary to re-program unless the customer has specific needs. If the controller does need to be programmed it can be done via a USB A to B cable and the Alltrax Toolkit program. Visit our website for more information on programming the controller including the Alltrax Toolkit Manual (DOC113-002) and instructional ...Alltrax SR48500 Motor Controller for Yamaha G9/G14/G16 (0-1K) Golf Carts Series. $639.00. Free shipping. See all 9.any instructions provided by Alltrax in verbal or written form. In the event you should need warranty repair, contact Alltrax at (541) 476-3565 to receive warranty service authorization instructions for returning the defective product to Alltrax for evaluation. Products or parts shipped by customer to Alltrax must be sent postage paid andCar fault codes can be a significant headache for car owners. When a warning light appears on the dashboard, it’s essential to know what the issue is to prevent further damage or p...Small 'pop' near controller. Alltrax error 1 Green, 6 Red Electric EZGOLED Blink Codes: At power up, # of green blinks indicates configured throttle type: 1 Green = 0-5k 4 Green = EZ-GO inductive (ITS) 7 Green = CLUBCAR 5K-3-wire Normal display status: Solid Green: Controller ready to run Solid Red: Controller in programming mode

Jackerman animations.

Kroger weekly ad tiffin ohio.

Downloaded Alltrax ap and plugged in. Don ended up remoting in and somehow the controller never saved his mapping and settings. He fixed it all over the phone and re-mapped it. Runs great now, just waiting on new lithiums to pair with it.(both red and green lights on) anyway - what model Alltrax control are you asking about NPX or AXE? Any other "fault codes" ? Can we assume this cart is built on a CC frame? Can you tell what the throttle input device is? ... Posts: 368 Re: alltrax controller. The alltrax controller is AXE 4844 400 amp with a date of 12/09/2005 S/N 27190 for a ...From the Alltrax web site: Note 2: Low Throttle range is the pedal "at rest OFF pedal position" The throttle could be faulty Wiring/connectorsSome Cummins engine fault codes include 111, which indicates an internal engine control unit failure; 214, which indicates that the engine’s oil temperature is too high; and 434, w...ALLTRAX XCT 48500 pds controller with fan from carts unlimited Heavy duty solenoid oredered with controller from carts unlimited July 2018 Trojan T605. 6 volt batteriesI have an Alltrax SPM 72400 and was having troubles with it. All I get is a single blinking green LED light. The single blink indicates a 0-5k throttle. I tried to clear and reset the throttle but the controller LED light never goes to a solid "ready" green. Also I get no throttle response when the throttle type is set to USB or absolute.Alltrax SR48300 Low voltage error in reverse Electric EZGOAlltrax SR48600 Pdf User Manuals. View online or download Alltrax SR48600 Operator's Manual ... Brands; Alltrax Manuals; Controller; SR48600; Alltrax SR48600 Manuals. Manuals and User Guides for Alltrax SR48600. We have 1 Alltrax SR48600 manual available for free PDF download: Operator's Manual ... Blink Codes. 29. Warranty Statement. 31 ... ….

Where can I find a user manual or other documentation for my home standby generator?Remove relay bracket. Mount relay on top of Alltrax controller using the stock bolts to secure the relay to the plastic inserts. Align notches in controller mounting flange with relay bracket holes in heatsink and secure with 2 bolts. The black cover can be re-installed over the DCX300 and DCX400 controllers but not over the DCX600 controller.DC motor controller for series and permanent magnet motors. ABS + PC510 flame resistant thermal plastic enclosure. All copper heat sinks. Sealed epoxy UL-94-VO / 5VA flame rating (best in industry) Adjustable undervoltage cutback 8-30 VDC. Adjustable overvoltage shutdown 22-62 VDC. Operating Frequency: 18k Hz.Caterpillar engine fault codes can be read with diagnostic software. This software is available at all reputable mechanics, or it can be purchased for use at home or on the road. T...Club Car Troubleshooting. CHECKING CONTROLLER INPUT and OUTPUT. Connect (-) probe to B- terminal. Connect (+) probe to B+ terminal. The reading should indicate approx. 0 volts with the resistor REMOVED and the pedal not pressed in the last 15-30 minutes. Slowly depress accelerator pedal until the solenoid engages.This fault will automatically clear and the charger will restart charging when this problem is removed. Check the battery and connections to the battery. Check the nominal battery voltage. The first two digits of the four digit model name indicate the battery voltage the charger supports.183 posts · Joined 2010. #1 · Sep 6, 2014. At the track pulled out the cars .Ella's car with the alltrax will not power up. Contactor locks in checked all fuses checked voltage on throttle o-4.75. No lights at all on controller can't check settings won't read on cp. Have voltage to the controller .battery voltage good.Controller is not powering up (No LED) Check for voltage on the wire attached to the RED J1 terminal. Verify wiring to the J1 terminals are correct Call Alltrax Tech Support LED blinks 1 green and 1 red Short Circuit/Output Fault Check B+, B- and M- connections on controllerAlltrax speed controller disappointment. Just got CC IQ decided to upgrade. Upgrades include plum quick bandit. Lift kit. 23 inch tires. Alltrax 500 amp. Kart was going 25 mph with new PQ motor & stock controler on speed 4 setting. Kart is now going 20 with new Alltrax contoler. Has a little more torque off line but the power falls off and it ... Alltrax controller fault codes, Connected Alltrax to laptop, now error codes Electric EZGO, Sorry to hear he is running on 36v. I seriously thought it was on 48v. If the old controller was a DCX as I suspect, then yeah, there is no speed sensor connection as of yet. Owner can disable limit rpms in the controller settings and enjoy unbridled speed at his own risk as he did with the old DCX control., Re: alltrax controller 48500 issues. I had exact same issue on my clubcar i2 excell - turns out the throttle was set for a ezgo - when i switch it to clubcar MCOR it worked perfectly. Switching the throttle type was locked by default in my configuration so I had to unlock it in the advanced settings window first., from Alltrax and it is not necessary to re-program unless the customer has specific needs. If the controller does need to be programmed it can be done via a USB A to B cable and the Alltrax Toolkit program. Visit our website for more information on programming the controller including the Alltrax Toolkit Manual (DOC113-002) and instructional ..., ALLTRAX Inc. 1111 Cheney Creek Road Voice: 541.476.3565 Fax: 541.476.3566 Alltrax TOOLKIT Instruction Manual These instructions cover: Installing Controller Toolkit V2.0 and newer Programming Troubleshooting Doc# Doc113-002 Revision: C ECO: EC-061115, Alltrax Inc PO Box 510 Murphy, OR 97533 Phone: 541-476-3565 Send requests and comments to: [email protected], 01-23-2022, 10:14 AM. # 1. dirtmann63. Not Yet Wild. Join Date: Jan 2022. Posts: 5. Bad Boy Buggy Controller Codes. I have a Bad Boy Buggy Classic that I recently bought. It has a green box with FSIP on the back w/ a silver box sitting on top with the following: 10-000523; BBB Classic; Field Retrofit Controller., Custom Motor Master List. Custom Built Series. Yamaha 36 Volt. 36 Volt Torque Venom *TOP SELLER*. 36 Volt Torque & Speed Coyote *TOP SELLER*. 36 Volt Torque & Speed Cyclops. 36 Volt Torque & Speed Grey Wolf. Yamaha 48 Volt. 48 Volt Torque Ganglord *TOP SELLER*., Re: Alltrax SR48500 low throttle input underrange. Quote: Originally Posted by JohnnieB. Across J4 and J5 with the white and black wires attached ought to be 10V when solenoid clicks and 6V with pedal on floor, so both of the readings you got were way out of range on the low voltage side. Disconnect the white and black wires from J4 and J5 and ..., prograMMing THe ConTroLLer 28 BLink CoDes 29 WarranTy sTaTeMenT 32 ... The fuse must be rated for pack voltage and fault current. 12 XCT OPERATORS MANUAL Wiring Controller Min. Wire AWG Standard Duty Min. Wire AWG ... system to allow for faster installation of Alltrax Controllers. Using the original mounting holes, the adapter plate bolts to ..., I fully charged the new set and went for a ride this am to my dismay, the battery voltage on full charge was dropping and staying between 44-45 volts under load on the flat). I'm still getting 31 mph out of the motor but the volts arent right and the amps are high which is going to put the heat back into the controller., Re: alltrax controller 48500 issues. I had exact same issue on my clubcar i2 excell - turns out the throttle was set for a ezgo - when i switch it to clubcar MCOR it worked perfectly. Switching the throttle type was locked by default in my configuration so I had to unlock it in the advanced settings window first., Hardware: Use a STRAIGHT-THROUGH DB-9 pin / RS-232 serial interface cable to connect the controller to the PC. Alternatively use the preferred DB-9 pin RS-232 serial port to USB adapter. The DCX controller must be powered before the ControllerPRO program will have any effect. Before programming the DCX, READ THE SAFETY NOTES BELOW., ALLTRAX Inc. 1111 Cheney Creek Road Voice: 541.476.3565 Fax: 541.476.3566 Alltrax TOOLKIT Instruction Manual These instructions cover: Installing Controller Toolkit V2.0 and newer Programming Troubleshooting Doc# Doc113-002 Revision: C ECO: EC-061115, An Advanced Motor Controller for Today's Demanding Markets. Thermal plastic enclosure ABS; 24-72 volt models; 650RMS amp models; Standard connectors for EZGo RXV, Club Car, EZGo TXT, ICON 22-23, YDRE2 *To come Yamaha G19/G22, PDS and YDRE ... Alltrax Inc PO Box 510 Murphy, OR 97533 Phone: 541-476-3565 Send requests and comments to: [email ..., Maytag washers are known for their durability and reliable performance. However, like any other appliance, they can occasionally encounter issues that may display error codes on th..., Ezgo txt alltrax spm48500ez throttle type troubleshooting: Electric EZGO: Swapping Alltrax AXE 7245 450a for Alltrax SR 72500 500a: Electric EZGO: …, Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV., Sep 15, 2017 · Re: Alltrax xct 400 pds blink codes. Seems the throttle is off a bit. XCT Control: B- to the small white wire in the 4pin plug on PDS cart. Just sitting there with everything powered should be 8-10V and at full pedal press 6-5V., Trouble Shooting. Error code display:# of RED blinks. indicates any error conditions that might. exist: 1 Red = Throttle Position Sensor Over. Range. Check for open wires. 2 Red …, Alltrax trouble code #2 Electric EZGO. Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV., Kaiser Car Pdf Manual Electric Wiring Diagram Fault Codes Dtc. Electrical Wiring Asn 263843. 1942 John Deere A Wiring Antique Tractors Forum. 1955 1960 Ford Tractor Series 600 700 800 900 1801 Service Manual. Ford 600 12 Volt Converison Wiring Diagram My Tractor Forum. Instrument Panel Gauge Kit 12 Volt 4 Sd Transmission For Ford 801 901 And 4000, With the CANUSB plugged into your computer, search the start menu for "Device Manager", and you will likely see a section in the middle called "Other devices" and the CANUSB will be there. It may look similar to this. If you see this, we know the issue is missing drivers. Use the download link in section 2 above., It's a frame I got from my father in law. I know nothing was ever changed or upgraded. I bought new batteries, and did an upgraded new alltrax controller and a D&D motor. When I bought the controller, the company actually sent the wrong one as the plug on it didn't match my plug. I called and they sent the correct one. They originally ..., 2. Alltrax has higher peak and sustained outputs than any other make. Basically a 400 amp control allows 460 amps and a 500a control allows 570a which is more bang for your buck. 3. Alltrax has integrated thermal plastic heatsinks and a built-in cooling fan so it mounts and cools safely on any surface. 4., Alltrax SR48400 Pdf User Manuals. View online or download Alltrax SR48400 Operator's Manual ... Brands; Alltrax Manuals; Controller; SR48400; Alltrax SR48400 Manuals. Manuals and User Guides for Alltrax SR48400. We have 1 Alltrax SR48400 manual available for free PDF download: Operator's Manual ... Blink Codes. 29. Warranty Statement. 31 ..., ALLTRAX Inc. 1111 Cheney Creek Road Voice: 541.476.3565 Fax: 541.476.3566 Alltrax TOOLKIT Instruction Manual XCT – SR - SPM These instructions cover: Installing Controller Toolkit V3.7 and newer Programming Troubleshooting, SPM, XCT, and SR controllers Doc# Doc113-002 Revision: E ECO: EC-041818, have a 1995 ezgo TXT 36 volt with an Alltrax DCX 400 controller . The cart was giving me problems that pointed to bad batteries, so I upgraded and went with a set of lithium. ... DCX fault codes attached. Attached Images. DCX LED status codes.jpg (41.9 KB, 0 views) 07-01-2020, 08:53 AM #5: Sergio . Gone Wild . Join Date: Sep 2012. Location ..., I am assuming the controller is still fine and the SW 202 has gone bad (it is 5-6yrs old and gets used just about everyday playing golf) Any advice or help would be appreciated. Thanks, Alltrax Kits Alltrax AC/AC Kits Alltrax DC/AC Kits Other DC/DC Kits Upgrade Controllers ... Zapi Controller Fault Codes . Zapi FC1001 & FC2125 Codes. Zapi FC2086 Codes. Zapi FC2125 Codes. Zapi FS2110 & 2042 Codes. Zapi FZ5017 & 5018 Codes. Zapi H2 Pump Controller Codes., Sudden speed interrupting a smoothly running golf cart can be equally frustrating and risky. When the speed controller fails to connect with the speed sensor, it gets confused and increases the speed abruptly. 7. Unable to maintain a constant speed. If the controller has gone bad, you may find your cart unable to maintain a constant speed., Controller is not powering up (No LED) Check for voltage on the wire attached to the RED J1 terminal. Verify wiring to the J1 terminals are correct Call Alltrax Tech Support LED blinks 1 green and 1 red Short Circuit/Output Fault Check B+, B- and M- connections on controller, Check out these Sevcon controller manuals for fault codes and troubleshooting assistance. ... Alltrax AC/AC Kits ... Fault Codes. Sevcon Micropak - PowerpaK Codes. Sevcon MOS90 Codes. Sevcon PowerpaK Codes . Software. Sevcon DVT Customer 2022 . Headquarters