Ground for 400 amp service

AT&T unveiled its streaming TV service, DirecTVNow, which will offer more than 100 channels for $35 a month and a Taylor Swift show. By clicking "TRY IT", I agree to receive ne...

Ground for 400 amp service. 20 amps require 12AWG. AWG is the preferred means of quantifying wire thickness for most people. Although, if you prefer a different unit of measurement, 12AWG equates to 0.0808 inches (Diameter), 2.053mm (Diameter), and 3.31mm2 (cross-section). 20 Amps Compatibility.

We have seen plans from engineers specify 3/0 for a 1200A service and a few specify 500MCM for a 2000A service. My understanding is when using a UFER ground you need 20’ of #4 Copper or 1/2” Rebar minimum in the concrete and are not required to have larger than #4 AWG copper between the electrode and the main service no matter …

A 400 amp service is a type of service that provides a higher level of electrical protection than a standard service. 400 amp services are typically used in industrial and commercial settings where high-powered equipment is located. These services can also be used to provide additional electrical protection for large facilities that may have ...Ground an outlet: $25 to $100: ... Now, 200-amp service is common for most homes, and 400-amp service is often installed for very large homes with many electric appliances, such as swimming pool heaters and radiant floor systems. Rewire a House . The cost of rewiring a house ranges from $1,600 to $11,400.The final option that may be available to you, depending on what your utility thinks of customer-provided meter mounting hardware, would be to use a single-disconnect, 400A meter-loadcenter combination to supply the service disconnect, emergency disconnect, and bonding/grounding electrode connection point.For a 400-amp service, you will need a wire size of at least 350 kcmil for copper wires or 600 kcmil for aluminum wires. It’s essential to adhere to the National Electrical Code (NEC) and local regulations, and consult with a qualified electrician to ensure proper installation and safety. 400 amp Service Wire Size Chart:Problems with the ground circuits to headlights can cause them to dim or not operate at all. The ground circuit provides a path for the electricity from the headlight to return to ...

That said, a 400-amp service will give you a lot more flexibility. You can have two good sized 200 amp panels in different parts of the house, Each panel will hold around 40 breakers. This allows more runs, and shorter runs from the panels to the outlets and other devices. Shorter runs mean less voltage drop that means less heat generated in ...Dec 26, 2014. #1. Have 2 - 200 amp main panels located in garage that are being fed by 4/0 Al conductors. Each panel is wired to the meter but am unable to look in the meter to see how it is done (double tapped or double lugged). Well under 200 amps needed for a 1400 sf house that has been upgraded from baseboard heat to heat pump.United States. Apr 21, 2003. #6. Re: 500KCMIL and 400A breaker Unless the breaker is 100% rated, the maximum load you can apply continuously is 320amps. The NEC requires the feeder conductors to have a minimum ampacity of not less than the noncontinuous load plus 125% of the continuous load.Electrical - AC & DC - 400 amp service with two 200 amp disconnects - I have a new 400 amp service on a shop. The meter base, with double lugs, is 15' from the shop. i plan to put the two outdoor 200 amp disconnects on the outside of the shop. I also have two 200 amp breaker panels for inside, one is 20' from thethe ground rod and the concrete-encased electrode shown here are the maximum sizes required by the NEC based on 250.66(A) and (B). If the GEC from the service equipment is run to the ground rod first and then to the water pipe, the GEC to the ground rod is required to be sized based on Table 250.66 as if it were run to the water pipe electrode.

10-01-18. ER 19-240-M. PAGE 2OF 7. SERVICE ENTRANCE - OVERHEAD. Single & Three Phase 100, 200, & 320/400 Amp. 1. GENERAL: 1.1 Residential electric and gas meters should bot h be located on the same side of the home within the front 1/3 to aid meter reading, testing and se rvice, and to aid emergency response in the event of a fire or some other ...Bonding and Grounding . Grounding Electrode Conductor for 1200 amp Service, Thread starter wirenut46; Start date Jun 3, 2015; Status Not open for further replies. ... Grounding Electrode Conductor for 1200 amp Service, Thread starter wirenut46; Start date Jun 3, 2015; Status Not open for further replies. W. wirenut46 Member. Location United States.Check out 250.66(A) which states that the sole connection from the service bond to the first ground rod shall not be required to be larger than 6 AWG copper or 4 AWG aluminum. Now look at 250.53(C) which requires the conductor connecting multiple ground rods to be sized in accordance with 250.66 which requires that you use table 250.66....May 1, 2020 · After using the demand factor of 44 percent (7 apartments) I came up with 214 amps per panel. 25,000 x 7=175,000 x 44 % =77,000 ÷208÷1.732= 213 amps. So I installed (2) panels 400 amp 3 phase to distribute the load. 14 apartments total and 7 on each 400 amp panel. I'm assuming I could have installed (2) 300 amp panel to take care of the total ...Turning this main breaker to the off position shuts off power to the entire house and all the branch circuits. The amp rating on this main circuit breaker identifies your electrical service size. If you have a 400 amp service, you will have two 200 amp main panels and each will have a 200 amp main breaker.350 Amps. 350 kcmil Copper Wire. 500 kcmil Aluminum Wire. 400 Amps. 400 kcmil Copper Wire. 600 kcmil Aluminum Wire. This table is quite easy to use. For example, let's say you are trying to figure out the feeder wire size for 300 amp service. By checking this table, you can see you will need either 4/0 AWG copper wire or 300 kcmil aluminum ...

The iron claw showtimes near marcus lincoln grand cinema.

In general, a 100 amp circuit's ground conductor must be at least # 8 AWG copper. Also, do you know what size ground is required for a 400-amp service? MIN. FOR GROUNDING RACEWAYS, SIZE OF EQUIPMENT GROUNDING CONDUCTORS (EGC). So, what size grounding rod do I require? 100 8 6 200 6 4 300 4 2 400 3 1. Ground rods are available in 8-foot and 10 ...400 amp 3 phase 4w UG service conductor sizing. Thread starter Steviechia2; Start date Nov 2, 2012; Status Not open for further replies. ... Multiply by 2 and you have 410 amps but at 80% you only have 328 amps so it would have to be a 350 amps breaker not 400 . C. Cow Senior Member. Location Eastern Oregon Occupation Electrician Nov 2, 2012 #6 ...Upgrading to 400 amp service. Have already set my two grounding rods and ran #2 solid for them. My question is about the water bonding. Existing water bond was (to my understanding) done wrong...but not noticed on inspection. It was attached to a hose bib on the opposite side of the house (60') from where the pipe enters the ground.400 amp service requires a wire size of 1,000 kcmil. What gauge wire is required for ground rod? The NEC code specifies that a solid copper wire used to connect to a ground rod must be at least either #6 or #8 gauge (depending on the size of your electrical service cable). #6 cable cable will always satisfy the sizing requirement, though in ...

Seems counterintuitive to reference a table dealing with bonding a raceway vs a system ground. unless you guys have a local rule it's 6 for your system ground. doesn't matter if it's a 100 amp single phase or 1200 amp 3 phase service. it USED to be different (i think 2 code books ago) Ontario, Canada 10-114 CEC states minimum #6AWG Copper but ...Kenwood - 400W Class D Bridgeable Multichannel Amplifier with Variable Crossovers - Gray. Model: KAC-M1814. SKU: 6330252. (97) $169.99. Open-Box: from $47.99.Per Article 250 of the NEC , The minimum size for a grounding conductor for a circuit protected by a 200 amp breaker is #6 copper or #4 Aluminum. This conductor may need to be increased in size for any of several reasons, including the length of the run, available fault current or other reasons that would fill a book.Aug 12, 2021 · (1) For a service rated 100 through 400 amperes, the service conductors supplying the entire load associated with a one-family dwelling, or the service conductors supplying the entire load associated with an individual dwelling unit in a two-family or multifamily dwelling, shall be permitted to have an ampacity not less than 83 percent of the ...I have a 400 amp heavy up going on and I have a few questions about grounding... I have 2 outdoor main disconnect switches and it has been a few years since... Menu. Home. ... 400 amp service. Thread starter eddie722; Start date Oct 6, 2010; Status Not open for further replies. E. eddie7222. YES you can use #4 Al as your ground. Your 1AWG Al is good for a 100 AMP feeder (actually 110). From NEC 250.122 this requires an #8 CU or #6 Al ground wire as a minimum (or 6CU and 4 Al if you …New Home 400 amp service [ 3 Answers ] I brought in 400 amp to my outside meter for my new log home. I had planned to split off 200 to the house and 200 to a future shop. However I don't think 200 will be enough from time to time. One expert I asked said I would be running at 600 AMP requirement. I think he is nuts.But let’s first look at what constitutes an equipment grounding conductor (EGC) and how it differs from the oft-misunderstood grounding electrode conductor (GEC) that connects noncurrent-carrying metal parts of the electrical service to the electrode buried in the earth. EGCs VS. GECs. Equipment Grounding Conductor (EGC): Table 250.122

Copper, aluminum and copper-clad aluminum equipment grounding conductors of the wire type shall be not smaller than shown in Table E3908.13, but they shall not be required to be larger than the circuit conductors supplying the equipment.Where a raceway or a cable armor or sheath is used as the equipment grounding conductor, as provided in Section E3908.9, it shall comply with Section E3908.4.

For a service rated at 100 through 400 amperes, the service conductors supplying the entire load associated with a one-family dwelling, ... Any additional grounding electrodes used shall be bonded to the electrical service grounding electrode system, or where provided, the lighting protection grounding electrode system. ...In this video you’ll see how the grounding electrode system is installed at a single-family dwelling. This system consists of (1) #2 AWG Aluminum grounding e...For the service wire, 150' isn't quite far enough to have to worry about voltage drop. Service and feeder to a dwelling is entitled to a favorable derate at 83% of service size. So 400A x 0.83 = 332A. You need wire rated for at least 332A at 75C thermal. That works out to 600 kcmil aluminum. (340A).400-amp services are rare. You will be hard-pressed to find a 400A service in a home because most residential properties do not require that kind of power. The amp service is more likely to appear in a large house with massive, heavy-duty appliances like pools.We would like to show you a description here but the site won't allow us.The Hobart 770031 400-Amp T-Style Ground Clamp is a favorite among many welders as well. It is one of the best gadgets on our list for managing current because it can sustain 400 amps. Since each component was cast rather than stamped, it is stronger. As you can anticipate, this leads to a clamp that is typically very strong.As we can see, 108A 00 (2/0) AWG aluminum hot wire needs to be grounded with a 2 AWG aluminum ground wire. 2 AWG aluminum ground wire can also be used to provide 100 amp service to sub-panels that are 50, 100, 150, or 200 feet away from the source.; In summary, you need to use: 8 AWG ground copper wire for 100 amp service (grounding 3 AWG copper hot wire).600AL is 340 amp conductor. Using 600AL on a service with single main 400 amp OCPD is noncompliant even using the "round up" rule as 350 amp OCPD's are available. A person needs to select a conductor size with an ampacity past 350 amps to be able to select the next size up 400 amp OCPD assuming the calculated load is less than the conductor ...

Double list wichita.

3176c irs letter 2022.

For a 400 amp service with aluminum, aim for a 1,000 kcmil wire. And for the ground, a 1 AWG aluminum wire should do the trick. So here’s a quick recap for you: Copper: Go with 600 kcmil for the main wire and 3 AWG for the ground. Aluminum: Opt for 1,000 kcmil for the main wire and 1 AWG for the ground.About this chapter: Chapter 36 is the first of the logical order of chapters that mimics the normal sequence of dwelling construction. The first step in dwelling wiring is typically the sizing, design and installation of the service that is the source of power for the building. This chapter addresses the sizing of services, service conductor sizing and installation, system grounding and ...Customer Service Phone: 800-572-1113 Southwestern Power Customer Service Phone: 888-216-3523 AEP Ohio Customer Service Phone: 800-672-2231 Public Service of Oklahoma Customer Service Phone: 888-216-3523That said, a 400-amp service will give you a lot more flexibility. You can have two good sized 200 amp panels in different parts of the house, Each panel will hold around 40 breakers. This allows more runs, and shorter runs from the panels to the outlets and other devices. Shorter runs mean less voltage drop that means less heat generated …The 400 amp welding ground clamp is constructed from copper alloy for excellent conductivity. The ground clamp has a large contact area for positive grounding. The high strength spring ensures solid ground contact. Large hex screws for safe cable connections. Heavy duty copper alloy construction; Large contact area for positive groundingThe right wire size for an 80 amp breaker is a 2 or 3-gauge wire. It is thick enough to carry the current produced by the 80 amps service. The 4 gauge wire is sometimes also considered the standard size for 80 amps. If you use aluminum wires, the size would be 1 or 2-gauge wire. The wire size can vary based on factors like the wire …A ground rod is a reference point for your system neutral. Fault currents are trying to get back to the source and usually take the path of least resistance; the neutral conductor. This is evidenced by the new code rules for grounding and bonding. A #6 is all that's required to the grounding electrode because it's primary function is as a ...What size ground rod do I need for residential 400amp service? NEC 250.52 (A) (5) Rod and Pipe Electrodes. Rod and pipe electrodes shall not be less than 2.44 m (8 ft) in length and shall consist of the following materials. (a) Grounding electrodes of pipe or conduit shall not be smaller than metric designator 21 (trade size 3∕4) and, where ... ….

Underground Service Rev. 1.10.20 GROUNDING: 1. National Electric Code approved grounding required. For 200amp service, bond enclosure with #4 bare copper. For 400amp service, bond enclosure with #2 bare copper. 2. Ground wire between meter enclosure ground lug and ground rod shall be continuous with no splices. CONSTRUCTION HOTLINE 1.866.992.6619According to the 83% NEC rule, a wire for 100 amp service has to handle at least 83 amps (have at least an 83A ampacity). That means that we don't have to use the 4 AWG wire; we can use the 3 AWG wire because it has 85A ampacity which is higher than the 83A required ampacity. 310.12 (B) Feeders part. Same as the (A) section but for feeders.We would like to show you a description here but the site won't allow us.At the big 400 amperes current, the voltage drop is less significant. To help you out, we have prepared 2 charts for running a 0-500 feet wire for 400 amp service at 120V and 220V voltages. The 1st one accounts for a 3% allowable voltage drop, while the 2nd one accounts for a less rigorous 10% allowable voltage drop.Aug 23, 2007. #1. We have a 3000 amp 208/120 volt service. It starts at the POCO's pad mount transformer then to an outdoor CT enclosure. From there it goes under a slab to a 3000 amp MCB switchboard. It has 8 sets of 4-500 kcmil feeders. We use Table 250.66 which says to use a 1/0 for each service feeder. Since the CT enclosure is before the ...A 400 amp panel refers to an electrical panel capable of handling a maximum current of 400 amps. While primarily utilized in commercial and industrial settings, it can also be suitable for larger residential homes. Typically constructed from steel or aluminum, 400 amp panel boards incorporate multiple circuit breakers to safeguard individual circuits from overloading.Ground Wire Minimum is #4 AWG Copper. A 200-amp service must have a #4 AWG copper wire or a #2 AWG aluminum wire running from the grounding electrode system to the main power panel. There will be a green screw that needs to be installed called the main bonding jumper. This bonds the panel to the neutral/ground bar.Texas properties are the first listed on a new platform allowing people to use bitcoin to buy residential and commercial real estate in the US. Jump to People who want to use crypt... Ground for 400 amp service, 400 kcmil: 2.5 inch: 350 Amps: 400 kcmil: 600 kcmil: 3 inch: 400 Amps: ... The ground rod for a 200 amp service must be 5/8″ (0.625) in diameter. It should also be 8 to 10 feet long and have a clamp and the correct ground wire. You should drive the ground rod 8 feet deep and cut it back close to the ground level. The wire and clamp must be ..., Shop 400/600A Service Grounding Kit For General Duty Safety Switch By Square D (Schneider Electric) (PKOGTA2) At Graybar, Your Trusted Resource For Disconnect Accessories And Other Square D (Schneider Electric) Products., 600, 800, 1200, 480 3 phase temp services have only two ground rods. What size ground rod is needed for a 400 amp service? Two ground rods should be at least 6′ apart. The ground wire should be 1/0 copper with a rod 4 to 6 below grade., The load site of meter panel feeds a 400 amp (fused) disconnect switch (again, located outdoors, parallel runs from the meter panel to the disconnect switch). All of this so far is installed. The meter panel and the disconnect switch are side-by-side. Next up is to install two outdoor 200 amp load centers (with main breakers) from the dual load ..., Normally a 400 amp service would need 1/0 or possible #2 copper for the grounding electrode conductor but the code states there is no reason to be larger than #6 to the rods, as Jim posted. I think the reason is that an 8' rod in the soil will do no better than the equivalent of a #6 wire so they gave us a break. lol. Dangerous DIYer., For a 400 amp service a #3 bare copper conductor is to be used for a 300 amp service. The Proper ground wire is determined based on the size of the main feeder wires. 400Amp single phase dwelling service wire is 400 MCM copper or 600 AL (NEC 310.15 (B) (6) Then ground wire is either #1/O Copper or # 3/O Al (NEC 250.66), A ground fault circuit interrupter (GFCI) must be rated at 200 amps at a minimum. The grounding electrode system must be sized as a #2 AWG exposed wire if you have a metal grounding receptacle with an aluminum sheath. That means you can go no larger than #2 AWG for 200-amp service. There is a no smaller size that conducts electricity and still ..., 400 Amp Meter Base Wiring Diagram - 2 - Installing 400 amp meter base. Water service (grounding) Grounding water service electrical conductor electrode nec house sizing fig progress diychatroom f18 calculations six part bar Installing 200 amp meter pole for mobile home. what size wire for a 80. 100 amp ground wire size. Ampacity conductor table ..., The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). Search Amazon for your Electrical ..., Leon County requires a 400A meter base (2 parallel sets of feeders, 3/0 copper or 4/0 aluminum), with 2-200A main breakers serving 2-200A MLO panels. The City of Tallahassee requires a 400A meter base with internal 400A breaker/means of disconnect, with 500MCM cable feeding panel 1 with double lugs to feed through to panel 2, both panels with ..., If you have a 320 (400) amp meter base with 2 - 200 amp panels, one on each side usually, then a #2 copper is all you need, however if you are using a meter main panel then 1/0 copper is needed based on the notes to 250.66. Based on power company wire which is 350 kcm then a 1/0 is called for in 250.66 that is 1/0 aluminum. Hambone8780., The term 400 amp service means the capacity of your home electric service. The capacity is actually measured by the amp. This also means that the current flows through the wire. So, in simple terms, the whole 400 amperage current flows through the wire and its maintenance is the 400 amp service. Making an upgrade on your …, What size wire for 100 amp service 50 feet away? The size of the wire for a 100-amp service 50 feet away would depend on factors such as the voltage and local electrical codes. Typically, this might require 3/0 or 4/0 copper or aluminum conductors. ... A neutral wire should ideally read close to zero voltage when measured with respect to ground ..., 1. This is a 320 class meter. Designed for 320 amp continuous and 400 amp intermittent. The above are possible acceptable catalog numbers. Extensions only needed if required for height reasons. 2. 320 amp meter sockets are acceptable for OH if UL listed, ringless, have a bypass lever, and have no cover over the meter. 3., For a 100 AMP service, the recommended wire sizes are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. If the distance is more than 50 feet, it’s advisable to use #2 AWG copper wire. For underground service, you can install the wire inside a 1.25-inch PVC conduit, either Sch 40 or Sch 80., 400 amp service/ grounding and bonding. peco are bringing direct burial wires underground to my meter socket, I am going pipe into the bottom of my 320 meter socket. I then will have 2 200 amp disconnects one on left of meter socket and one on right, I am going to have a double lug in my meter and run 4/0 to my disconnects, then from my ..., 2. YES you can use #4 Al as your ground. Your 1AWG Al is good for a 100 AMP feeder (actually 110). From NEC 250.122 this requires an #8 CU or #6 Al ground wire as a minimum (or 6CU and 4 Al if you …, Jun 9, 2021. #6. If a customer wanted 400 amp 240v 3 phase, I would most likely install one 240v 3 phase panel strictly for 3 phase loads, and a 240v single phase panel for line-neutral 120v loads. The last time we needed 240v 3 phase, I had to step it down from 480v and ran into the same 5% issue., Copper, aluminum and copper-clad aluminum equipment grounding conductors of the wire type shall be not smaller than shown in Table E3908.13, but they shall not be required to be larger than the circuit conductors supplying the equipment.Where a raceway or a cable armor or sheath is used as the equipment grounding conductor, as provided in Section E3908.9, it shall comply with Section E3908.4., The ground wire for 600-amp service: When it comes to the ground wire, we will need 1-kcmil gauge wire of copper wire and Aluminum 2/0-kcmil wires. Aluminum wire for 600-amp service: Now the size of aluminum wire for 600-amp service is 2000 kcmil. Copper wire for 600-amp service: In this case, we always need to follow a rule of thumb., A 100-amp main breaker panel receives 100-amp service at 240 volts. Electricity enters the home via the meter socket and service-entrance wire. Two-gauge, three-conductor aluminum ..., I have a 400 amp Siemens main panel it has a 200 Amp breaker to the house and a secondary 150 amp breaker added to run power to a metal building approximately 150 feet from the main. what size wire ... Also grounding the panel to the building and to the ground rod what size wire would be adequate? ... From the Main Panel SER 4/0-4/0-4/0-2/0 ..., The ordinary code of wire to use for a 200 amps service panel is #2/0 copper wire that needs to have a conduit of 2 inches. The electric code of your country may also set the bar for utmost safety. For aluminum or copper-clad wire, there shall be a wire with a gauge of #4/0 AWG. The MCM rating would be 211.60 kcmil., So, if I want a 400A 120/240V residential service, then that is displayed by the presence of a 400A handle or a pair of 200A handles comprising the service disconnect. If I have this, then I can use the conductor size listed next to "400" on Table 310.15(B)(7). That is a "400A rated service.", The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). Search Amazon for your Electrical ..., 480V Delta or 277/480V Wye, 200 Amp & Below Service, Self-Contain Metering with Meter Disconnect Figure 16. Three Phase Self-Contained Meter Socket Figure 17. ... ground, grounding conductor, grounding electrode conductor, service conductors, service entrance conductors, overhead system, underground system, service equipment, service ..., What wire size is needed to ground a 300 amp service panel in USA? Notes: 1. Where multiple sets of service-entrance conductors are used as permitted in Section 230-40, Exception No. 2, the equivalent size of the largest service-entrance conductor shall be determined by the largest sum of the areas of the corresponding conductors of each set., 3 posts · Joined 2022. #1 · Jul 1, 2022. Hello all, I am installing a 400 amp meter base combo.I have seen plenty of example of 400 amp meter bases with separate 200 amp disconnects. These separate disconnects typically have a grounding bare and a hole punch to bring the grounding wire out through eco suit down to the grounding rods., Apr 19, 2009 · rgsgww Discussion starter. 1543 posts · Joined 2008. #1 · Apr 19, 2009 (Edited) I currently have a 400 amp service with two 200 amp service panels, the ground is a water pipe connected with what looks like 4 awg stranded. There is one rod with 6 awg solid. If I were to update the grounding system, wouldn't I need to sink rods for each panel?, For a 400-amp service, you will need a wire size of at least 350 kcmil for copper wires or 600 kcmil for aluminum wires. It’s essential to adhere to the National Electrical Code (NEC) and local regulations, and consult with a qualified electrician to ensure proper installation and safety. 400 amp Service Wire Size Chart:, Generally, the ground wire size for a 200 amp service ranges from 2 AWG to 8 AWG. The best one is 2 AWG for copper wire and 4 AWG for aluminum or copper-clad aluminum wire. It is recommended to use them with 1.5-2.5 inches schedule 40 or 80 PVC conduit for underground service. It may differ depending on the materials, permission …, OzEng, Thanks for the information.The soil is red clay with plenty of iron in it so there shouldn't be a problem there.The local building code chart guide only goes to 200 amp.It doesn't specify ground rod size just a depth of at least 4' in the ground and using #4 copper for the ground wire.The circuit length to the rod and back is 20'.The typical …, Dec 10, 2012 · I was hoping to get some advise for a service upgrade that I plan to do soon. I need to upgrade from a 200 amp to a 400 amp service. I plan to install the POCO 400 amp meter base and then connect 2- 200 amp disconnects in parrallel. My question is the termination of the GEC. There is a lug in...