Pentair mastertemp display not working

For a test replace the thermistor with a 10K resistor. If the temperature stays at 76F while the Aqualink heats the water to 101 then you have a problem with the thermistor. If the heater still will not heat to 101 then you need to check the thermal regulator or the bypass valve in the header. Last edited: Dec 23, 2021.

Pentair mastertemp display not working. Inspect & clean pump impeller. Adjust Plumbing valves. Repair suction air leaks. Make sure external water bypass around heat pump is closed. With water flowing, check resistance of water pressure switch, if open, replace switch. Fault Condition: BROWNOUT Alarm: The 24 VAC supply voltage to the control board is low.

May 22, 2021 · Pentair MasterTemp 250 Display Not Working. Thread starter manrose; Start date May 22, 2021; Jump to latest Follow Reply Forums. Equipment - Build, Benefit, and Remote.

I show you how to replace and install the Pentair Mastertemp 400 membrane pad. This membrane controls the many functions on the Pentair Mastertemp 400 pool ...Pentair MasterTemp Pool Heater Heater Display Cover 42002-0035Z. $42.47. 5.00 ... Very Quick! Add a review Cancel reply. Your email address will not be published.It's a fairly powerful heater and when working correctly, it'll quickly get the spa or pool to a nice temp. In recent months it's been doing something odd. The heater will kick in as expected right after the switch is flipped but after about 45 seconds or so, the "Service System" light goes on and the burner shuts off (but not the blower).Your Pentair pool heater display not working can be a result of a lack of power supply, a blown fuse, or a defective control board. Read our Pentair pool heater troubleshooting guide to solve this issue ASAP. Table Of Contents Pentair Pool Heater Display Not Working [3 Easy Fixes] 1. Lack Of Power Supply 2. Blown Fuse 3. Defective Control BoardThe common reasons why your Pentair MasterTemp 400 keeps shutting off are incorrectly set temperature control, incorrect wiring, low gas pressure, and a wet or damaged high-limit switch. Besides shorted or defective AGS, faulty ignition control module, clogged pool filter, faulty temperature sensor, and bad control board are also responsible …Jul 13, 2018. #1. Hi all! We just had our gas hooked up today and finally fired up the heater. We have a Pentair Mastertemp 400. It turns on, runs through the light show and displays the temperature. I can press "POOL" or "SPA" and the heater starts working. However, when I try to turn on the heater through ScreenLogic, the heater turns on ...In this video I will show you what steps I went through to troubleshoot the no heating issue with my Pentair MasterTemp 250 pool heater.#pentair #poolheater ...

Used this to replace a 10 yr old Pentair Mastertemp 400 control board that was failing. Solved the issue, easy to install. Information was not clear that it also included the keypad. Could have used more instructions for older systems especially when the Pentair control center is turning the heater on/off. Good Morning Everyone, We opened our pool a couple of past ago with no issues. We went to turn up the heat yesterday and the display that shows the temperature is no displaying anything. I am able to pressure to "pool on" button and this green lamp will show up, however, nothing appeared on the...Apr 4, 2022 · 3. Broken Thermal Regulator. A broken thermal regulator or thermostat is another reason why you may be getting the wrong temperature on your Pentair MasterTemp 400’s display. Solution: You can take out the thermal regulator and test its continuity. The Thermal Regulator is situated between the inlet and outlet fittings in the Inlet/Outlet ... Apr 23, 2020. #2. Check to make sure that the gas valve in the heater is in the On position. Check all valves on the gas supply line. Check the inlet gas pressure before the heater tries to fire and watch the pressure as the heater tries to fire. Check the voltage and current going to the igniter. The symptoms point to either no gas or no hot ...5. Low Water Flow. An obstruction in your pool system can prevent your heater from turning on due to limited water flow. Solution: Ensure that your pool filter is clean. Empty the baskets. Make sure the pump is sending enough water through the system. 6. Dirty Heat Exchanger.3. Broken Thermal Regulator. A broken thermal regulator or thermostat is another reason why you may be getting the wrong temperature on your Pentair MasterTemp 400’s display. Solution: You can take out the thermal regulator and test its continuity. The Thermal Regulator is situated between the inlet and outlet fittings in the Inlet/Outlet ...

I have a Pentair VS3050- Valves not turning, heater not working in SPA, and we're getting an 'err' on pool temp display. All started at the same time. Please help! …PENTAIR MASTERTEMP 400 turns on. Goes through the standard boot up procedure (128/R13 appear on the LCD of heater) Then the display shows "1". The heater fires up and starts heating for about 3-4 minutes. Then it errors out with E01... and keeps the code on for a long while. I check the back of the control board in the heater and the …Apr 5, 2021. #8. JamesW said: Put the system in Service Mode and then press the Filter button to start the pump. Make sure that the light above the Filter button is on. Once the pump is on, press the heater button to see if the heater will come on. The heater does come on when I do it in service mode.If the heater is on and blowing heat out of the exhaust then the heat needs to be going someplace. If the heat is not going into the water the heater will overheat and trip the SFS or HLS overheat safeties. LED11 is the Service Heater light. Heat not getting into the water could be caused by a bad thermal regulator, bypass valve, or scaled heat ...I had my pentair ultratemp heat pump control board replaced 1.5 years ago as it wasnt working, coukdnt adjust temp up or down. Then last summer, the whole heater stopped working. Seemed like the contr … read moreJan 20, 2022 · In this video I will show you what steps I went through to troubleshoot the no heating issue with my Pentair MasterTemp 250 pool heater.#pentair #poolheater ...

Raid clan boss dps champions.

The display will flash once and change modes (°C to °F or vice versa). 3. Turn the Operating Control ON. When either the ^TEMP or down TEMP buttons are depressed, the digital display will indicate the temperature setting. After five seconds, the display will return to the actual pool/spa temperature.Salt Water Generator. SWG Type. Pentair Intellichlor IC-60. Apr 17, 2021. #2. 128 r14 is the normal MasterTemp startup display. R14 is the firmware release on the heater.Oct 4, 2020 · I do have an ET. Based on these suggestions I may try to calibrate the water temp sensor from the ET and see if it will save. The main issue is it is not saving from the app. Or it’s faulty. This is what I understood. Please correct me if wrong. The ET sends the set point to the heater which kicks it on initially. ajw22. The Pentair burners are in a sealed burner pot and the only exits are the exhaust fan and the air intake. You have an air/gas mixture problem in the burners and when the mixture explodes the pressure can only be released through the exhaust and air intakes. That is why you see the air intake being blown off.Pentair Pool Heater Display Not Working [5 Easy Solutions] 1. Blank Display Board. If you notice that the display of your Pentair pool heater is blank or not showing any codes or... 2. Blown Controller Fuse. …April 9, 2023 by William. Pentair Mastertemp 400 common problems include displaying the wrong temperature, low water circulation, leaking water, water scaling, and corroded heat exchanger. Some other problems that Pentair Mastertemp 400 pool heater users face are the blower not working, not heating, not igniting, not turning on, knocking noise ...

How to de-bug / fix issues with a Pentair MasterTemp Heater. Craig Wooster. 5.64K subscribers. Subscribe. 317. Share. 100K views 2 years ago. if you have any questions please contact …if you have any questions please contact us through our website at: https://www.poolspecialists.com/Some famous Filipino sculptors are Rey Paz Contreras, Eduardo Castrillo, Solomon Saprid and Napoleon Abueva. A work by Napoleon Abueva, titled “The Sculpture,” has been on display in the United Nations headquarters.Everything in my Pentair Mastertemp Heater is working properly except the LCD screen that displays the temp. I can see that the backlight is coming on but there is no display of numbers. All buttons on pad work as normal and from reading other threads I realize the LCD screen is on the control board.Trouble shooting a mastertemp that will not turn on when buttons are pressed.Jun 11, 2023. #2. cactus_LV said: The pool has been filled for 2 weeks now so too early to turn on the heater (pentair mastertemp 400) but I wanted to see if it at least works (has power). And apparently it doesn’t - no light or anything on the display. Pumps, intellivalves and intellicenter work.1. Pentair Mastertemp 250 Not Igniting 2. Pentair Mastertemp 250 Not Heating 3. Mastertemp 250 Won't Turn On 4. Mastertemp 250 Keeps Shutting Off 5. Pentair Mastertemp 250 Air Flow Fault 6. Pentair Mastertemp 250 Cycles On And Off 7. Pentair Mastertemp 250 Heating Light Blinking 8. Pentair Mastertemp 250 Turns On By Itself 9.Chlorine. Liquid Chlorine. Jun 21, 2022. #1. Having trouble getting my EasyTouch to control the MasterTemp 400 (pool use). MT works fine when I manually control it on the MT panel. ET doesn’t seem to turn MT on or off when I turn on or off filter pump or on or off heat mode on ET, or adjust ET thermostat above/below current temp.To avoid this problem, clean the pipes and use soft water instead. 2. Inaccurate Temperature Control or Display. Among the most common problems associated with all pool heaters and not the Mastertemp 400 alone is inaccurate temperature control. In some cases, the water can become too hot or too cold.Reason 1: The flow of water to the heater has reduced. Solution: Servicing on the pump or on the filter will fix this issue. Reason 2: Plugging of the exchanger. Solution: Alter the chemistry of the water and reach an equilibrium. You could also take the heat exchanger for …If the ohms check out you are correct. Likely the board. Your unit doesn’t have a thermistor that checks the firebox temp. So I would change the thermistor and go from there honestlyYou can update me any time on thisbI hope that helps, If you don't mind, Please take a few seconds of your time and remember to rate the question positively with the stars on the top left.Oct 4, 2020 · I do have an ET. Based on these suggestions I may try to calibrate the water temp sensor from the ET and see if it will save. The main issue is it is not saving from the app. Or it’s faulty. This is what I understood. Please correct me if wrong. The ET sends the set point to the heater which kicks it on initially.

In today’s digital age, having a strong portfolio is essential for showcasing your skills and attracting potential clients or employers. However, simply displaying your work in a traditional format may not be enough to grab the attention of...

3. Broken Thermal Regulator. A broken thermal regulator or thermostat is another reason why you may be getting the wrong temperature on your Pentair MasterTemp 400’s display. Solution: You can take out the thermal regulator and test its continuity. The Thermal Regulator is situated between the inlet and outlet fittings in the Inlet/Outlet ...The Pentair MasterTemp common problems include- sparking failure, temperature issue, electric keeps shutting off, display not working and the heater not …Sep 21, 2018 · 39,895. Sep 21, 2018. #8. The buttons not working is usually a membrane issue. Since you replaced that, it points to a bad board. If you had the External Control Interface Circuit Enabled, the "Pool On" and "Spa On". keys would be disabled. The "OFF" Key on. membrane pad should remain functional. Salt Water Generator. SWG Type. Pentair Intellichlor IC-60. Apr 17, 2021. #2. 128 r14 is the normal MasterTemp startup display. R14 is the firmware release on the heater.I do have an ET. Based on these suggestions I may try to calibrate the water temp sensor from the ET and see if it will save. The main issue is it is not saving from the app. Or it’s faulty. This is what I understood. Please correct me if wrong. The ET sends the set point to the heater which kicks it on initially.Your Pentair pool heater display not working can be a result of a lack of power supply, a blown fuse, or a defective control board. Read our Pentair pool heater troubleshooting guide to solve this issue ASAP. Table Of Contents Pentair Pool Heater Display Not Working [3 Easy Fixes] 1. Lack Of Power Supply 2. Blown Fuse 3. Defective Control BoardHi Randy,Finally reached max level of frustration with the Mastertemp 250 HD Heater and Installed a new Mastertemp 250 HD Cupro-Nickel ASME version. Purchased from Pool Supply Unlimited however they w …Make sure the pump is on and that the cords are plugged in securely. ER 2: This code means there’s a problem with the heater’s flow switch. Check to make sure that the flow switch is in the correct position and that there is no sand or other debris blocking it. ER 3: This code means that the heater has overheated.Instant is one of the “Personality Kits” you select based on whether you want to control a separate pool or spa, a pool/spa pair to shared equipment oder one pool/spa combination using separate equipment. How to diagnose and settle a Pentair Mastertemp Swim Pool Heater - Splash Phd; Third is your Your Controller.

Sherry spa utica ny.

Linguee english polish.

May 27, 2017 · I got a pentair mastertemp propane heater installed last week. Its 400k btu model number 460737. Its seems to be working fine. Its connected to the main aquarite panel. When i keep it in pool mode on my aquarite control panel, turn on heater from the aquarite. The heater turns on , but the indicator on the display panel on heater shows 'spa'. Pentair MasterTemp transformer P/N is 42001-0107. P/N 42001-0107s is for units made after 2003. A bad transformer can cause the fuse to blow. If the MasterTemp heater display does not light up when heat is commanded then check the power beginning at the Circuit Breaker.My Spa heater is not working. It shows enabled but does not fire up and there’s nothing on the display. Contractor's Assistant: Who manufactured the spa? It is a pentair mastertemp. Contractor's Assistant: Do you plan on doing the work yourself? Don’t know, would to know what’s wrong before I schedule something.Aug 25, 2018 · 2. Seabrook, TX. Aug 26, 2018. #6. We have this same pool heater and have had to replace the button panel about six times. Finally, Pentair said they’d no longer cover replacing it and now we have to pay for it ourselves. The repair man said he believes water is getting in behind the “sticker” and shorting it out. Good Morning Everyone, Us opened our pools a couple of days ago over no issues. We proceeded to turn up who warmth yesterday and the display that shows the …My pentair 400 mastertemp is not heating the display is. my pentair 400 mastertemp is not heating the display is showing a r+8 128 code ... Heater not working. Still within 3 year warranty. Pentair. It didn't come on a few weeks ago.Apr 20, 2022 · Apr 19, 2022. #1. I have a Mastertemp 400 pool and spa heater. It does 1 of 2 things currently: 1) Reads in the inlet temperature in the 90s, water is likely in the 70s. Heater will kick on and heat for about a minute before the temperature rises to 126 rapidly and kicks off the heater. 2) When turned on the water temperature shows above 104 so ... A faulty control board can be a potential reason why you may be getting the wrong temperature on your Pentair MasterTemp 400’s display. The replacement process is risky & expensive. ... properly, make sure it is getting sufficient water pressure or not. The adequate water pressure for the pool heater to work normally is usually at least 40 GPM.if you have any questions please contact us through our website at: https://www.poolspecialists.com/It seems as though our heater already some level of rodent proofing already. Our heater has manufacturing date of 7/28/2020 and here’s some photos. There’s a reflective/mirrored metal plate that seals the gap behind the exhaust. There also seems to be no longer a gap around the water inlet/outlet “plate”.The 10 Best Pool Heaters of 2023. Raypak 014951 Digital Cupro-Nickel Propane 266,000 BTU Pool Heater. Pentair MasterTemp 125 Low NOx Pool Heater. Raypak PR266AENX51 240,000 BTU Heater …Apr 20, 2022 · Apr 19, 2022. #1. I have a Mastertemp 400 pool and spa heater. It does 1 of 2 things currently: 1) Reads in the inlet temperature in the 90s, water is likely in the 70s. Heater will kick on and heat for about a minute before the temperature rises to 126 rapidly and kicks off the heater. 2) When turned on the water temperature shows above 104 so ... ….

I have a Pentair HeatMaster 400 (1.5 years old) that does the following when I turn on the heater from the app or the EasyTouch panel: 1. Display comes on with "888". 2. service heater light on. 3. service system light on. 4. display shows "128 r14". 5. then display and lights turn off. I don't hear the heater "fire up" or may any noise (not ...A faulty control board can be a potential reason why you may be getting the wrong temperature on your Pentair MasterTemp 400’s display. The replacement process is risky & expensive. ... properly, make sure it is getting sufficient water pressure or not. The adequate water pressure for the pool heater to work normally is usually at least 40 GPM.If it does not open, then it is damaged and malfunctioning. You need to replace it with a new one. A poor manifold bypass. A poor manifold bypass can be a potential reason why you may be getting the wrong temperature on your Pentair MasterTemp 400’s display. Inspect & clean pump impeller. Adjust Plumbing valves. Repair suction air leaks. Make sure external water bypass around heat pump is closed. With water flowing, check resistance of water pressure switch, if open, replace switch. Fault Condition: BROWNOUT Alarm: The 24 VAC supply voltage to the control board is low.After powering up or turning on your Pentair pool heater, suddenly, it may fail to ignite mainly for the following reasons. Note: You can also read how to fix Pentair Mastertemp 400 common problems. 1. Defective Igniter. Igniter malfunction is one of the main reasons for which you may experience a Pentair mastertemp 400 ignition lockout …How to de-bug / fix issues with a Pentair MasterTemp Heater. Craig Wooster. 5.64K subscribers. Subscribe. 317. Share. 100K views 2 years ago. if you have any questions please contact …Apr 17, 2021 · Salt Water Generator. SWG Type. Pentair Intellichlor IC-60. Apr 17, 2021. #2. 128 r14 is the normal MasterTemp startup display. R14 is the firmware release on the heater. 5. Low Water Flow. An obstruction in your pool system can prevent your heater from turning on due to limited water flow. Solution: Ensure that your pool filter is clean. Empty the baskets. Make sure the pump is sending enough water through the system. 6. Dirty Heat Exchanger. Pentair mastertemp display not working, Mar 26, 2022 · Your Pentair MasterTemp 400 display not working generally means that your unit is not getting power, you have a blown glass fuse, or a defective control board. Solution: Ensure that the power outlet your Pentair heater is connected to is good and provides the appropriate amperage for the heater. , My Pentair pool pump stopped working, and I wanted to show exactly how I, as a DIY-er, troubleshooted the issue. The symptoms were: Pool pump was humming for..., Your Pentair pool heater display not working can be a result of a lack of power supply, a blown fuse, or a defective control board. Read our Pentair pool heater troubleshooting guide to solve this issue ASAP. Table Of Contents Pentair Pool Heater Display Not Working [3 Easy Fixes] 1. Lack Of Power Supply 2. Blown Fuse 3. Defective Control Board, Jun 21, 2022 · Chlorine. Liquid Chlorine. Jun 21, 2022. #1. Having trouble getting my EasyTouch to control the MasterTemp 400 (pool use). MT works fine when I manually control it on the MT panel. ET doesn’t seem to turn MT on or off when I turn on or off filter pump or on or off heat mode on ET, or adjust ET thermostat above/below current temp. , Pentair Mastertemp 400, Natural Gas, made/installed in 2016. Replaced a previous Hayward unit that lasted >10 years. There were no changes in gas line when this was replace. Pool is ~30,000 gallons with built-in spa, chlorine. Here is what is going on: Start up: 1., Pentair MasterTemp 250 Display Not Working | Trouble Free Pool | Pentair MasterTemp 250 Display Not Working Sound Sunrise Everyone, Were …, To avoid this problem, clean the pipes and use soft water instead. 2. Inaccurate Temperature Control or Display. Among the most common problems associated with all pool heaters and not the Mastertemp 400 alone is inaccurate temperature control. In some cases, the water can become too hot or too cold., 5. Low Water Flow. An obstruction in your pool system can prevent your heater from turning on due to limited water flow. Solution: Ensure that your pool filter is clean. Empty the baskets. Make sure the pump is sending enough water through the system. 6. Dirty Heat Exchanger., Re. P 82020 MASTERTEMP Pool and Spa Heater Installation and User’s Guide 5 SAFETY INFORMATION Section 2. Warning and Safety Instructions The MasterTemp® pool heaters are designed and manufactured to provide many years of safe and reliable service when installed, operated and maintained according to the information in this manual., Chlorine. Liquid Chlorine. Jun 21, 2022. #1. Having trouble getting my EasyTouch to control the MasterTemp 400 (pool use). MT works fine when I manually control it on the MT panel. ET doesn’t seem to turn MT on or off when I turn on or off filter pump or on or off heat mode on ET, or adjust ET thermostat above/below current temp., Mar 2, 2011. 40,366. Oct 24, 2021. #2. Turn the heater on. The fan will come on for about 30 seconds, then you will hear a click, and the heater should fire. At that moment, which ever thermostat you are using (POOL or SPA) hold that button down for ~10 seconds. Display should change from water temp to exhaust temp., For a test replace the thermistor with a 10K resistor. If the temperature stays at 76F while the Aqualink heats the water to 101 then you have a problem with the thermistor. If the heater still will not heat to 101 then you need to check the thermal regulator or the bypass valve in the header. Last edited: Dec 23, 2021., Reason 1: The flow of water to the heater has reduced. Solution: Servicing on the pump or on the filter will fix this issue. Reason 2: Plugging of the exchanger. Solution: Alter the chemistry of the water and reach an equilibrium. You could also take the heat exchanger for servicing., It's a fairly powerful heater and when working correctly, it'll quickly get the spa or pool to a nice temp. In recent months it's been doing something odd. The heater will kick in as expected right after the switch is flipped but after about 45 seconds or so, the "Service System" light goes on and the burner shuts off (but not the blower)., 39,895. Sep 21, 2018. #8. The buttons not working is usually a membrane issue. Since you replaced that, it points to a bad board. If you had the External Control Interface Circuit Enabled, the "Pool On" and "Spa On". keys would be disabled. The "OFF" Key on. membrane pad should remain functional., Sep 2, 2023 · Esthermatte Home Search Home Search Search , Mar 4, 2022 · Anybody would feel annoyed and panicked. But calm down as we have brought you the solutions for common problems that you face in Pentair MasterTemp 400. Problems like Off and On issues with your pool heater, water flow not working efficiently, the position of a heater, Temperature display, etc. These problems can be solved with just minor steps. , The Pentair Home app accepts a wide range of Pentair Connected water devices that can be used throughout a home to help your customers move, improve and enjoy their water. However, at this time, Pentair Home and Pentair Pro are not integrated with other smart home devices, or connected via voice with at home assistants like Alexa or Google Home. , jkmhb. Hello, as the title says. My (3.5 year old) Mastertemp pool heater is hooked to an iAquaLink, which I use to turn on/off and set the temp. The heater heated to about 85 degrees on spa setting, then gave up. At the heater, I could hear some clicking, but the heater does not come on. The panel had a really high number (like 113), but I ..., It depends on what the issue you are facing is. But most issues are fixable. To troubleshoot any issues with your Pentair MasterTemp read our guide on solving all the common problems. What does Flo mean by a pool heater? The FLO code indicates that the water flow to your heat pump has been halted by the filter pump., May 21, 2022 · Make sure the sensor is properly mounted. 2. Defective Thermal Regulator. If the sensor is quite in good condition and hooked to the control board easily, there is the suspect of a defective thermal regulator of the pool heater. Now, if the display is still showing the wrong temperature, you have to check out the thermal regulator this time. , Feb 1, 2017 · Trouble shooting a mastertemp that will not turn on when buttons are pressed. , E01 126 Error Burner Troubleshooting Heat Exchanger Troubleshooting How does a Pentair Mastertemp Swimming Pool Heater work? A Pentair Mastertemp heater is actually a very simple appliance that becomes more complicated due to all of the interlock protection., If it does not open, then it is damaged and malfunctioning. You need to replace it with a new one. A poor manifold bypass. A poor manifold bypass can be a potential reason why you may be getting the wrong temperature on your Pentair MasterTemp 400’s display., Apr 5, 2021 · Apr 5, 2021. #8. JamesW said: Put the system in Service Mode and then press the Filter button to start the pump. Make sure that the light above the Filter button is on. Once the pump is on, press the heater button to see if the heater will come on. The heater does come on when I do it in service mode. , Good Morning Everyone, We opened our pool a couple off days ago with no issues. We went in bend upside the heat yesterday and the display that schauspiel the..., Turn on the heat on the EasyTouch so the heater turn on and the front panel lights up. Press SPA ON. Then use the TEMP UP red arrow to raise the temperature to 104. Ignore the 319 in the picture below. Normally it displays the water temperature or the set temperature when you are adjusting it., In this video I will show you what steps I went through to troubleshoot the no heating issue with my Pentair MasterTemp 250 pool heater.#pentair #poolheater ..., Good Morning Everyone, We offene their pool a couple of days ago with no issues. We went to spin up the heat yesterday and the display that shows which cooling is not displaying anything. MYSELF am can into press the "pool on" button and the grow light will show up, however, nothing appears on the..., 5.0 (1 REVIEW) $107.78. Quantity. Pool Supply Unlimited has some of the best prices when shopping for Pentair MasterTemp Membrane Pad Kit | 472610Z., Jun 2, 2022 · Pentair Pool Heater Display Not Working [5 Easy Solutions] 1. Blank Display Board. If you notice that the display of your Pentair pool heater is blank or not showing any codes or... 2. Blown Controller Fuse. The display of the pool heater is connected to a fuse in the control panel in order to ... , Sep 7, 2016 · Mastertemp 125 is not working displays shows trouble code. ... Pentair Mastertemp - digital display shows water temp at 126 degrees. Control panel and remote show ... , Apr 19, 2015. #16. I am having a problem with my MasterTemp 400 heater. I went to turn it on today to heat the pool a little. The "pool on" light came on and the temperature display says 75 but the heater/blower did not start. Now, when I press the "heater off" button, nothing happens (the pool on and temperature display lights stay on).