Chart 410a pt refrigerant pressure temperature hvac condenser air 422b coupled ajn unit century 421a ton 3ton line set superheatCalc dupont R438a pt chartGet out in front of r-22 supply reductions with dupont™ isceon® mo99.

Pt chart for mo99. In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...

more Freon™ MO99 ™ or Freon™ NU-22B in small amounts (still by transferring as liquid from the charging cylinder), until the system conditions reach the desired level. See the pressure-temperature charts in this bulletin to compare pressures and temperatures, to calculate superheat or subcooling for the refrigerant.

R290 Charging Instructions for Central Air Conditioners. Determine the capacity of your system from the nameplate. It should state the capacity in ounces. Usually between 50 and 90. If it uses R33, Enviro-safe R290 would be the proper replacement refrigerant. If it uses R12 or 134, then use our Industrial 12a.Pt Chart For Mo99 - I replaced a 3.5 ton york r22 condenser with a 3.5 ton r22 rheem. Freon™ mo99™ has compatibility with all traditional and new lubricants,. Traditional pt charts list the saturated refrigerant pressure, in psig, with a column for temperature down the left side.The tips below will help you fill in R438a Pt Chart quickly and easily: Open the form in our full-fledged online editing tool by clicking Get form. Fill out the requested fields which are marked in yellow. Hit the arrow with the inscription Next to move on from box to box. Use the e-autograph tool to add an electronic signature to the form.Freon™ MO99 is different than other R-22 replacements on the market, because it doesn't require costly oil or equipment changes, it's manufactured using anti...[ベスト] r-290 pt chart 142052-r 290 pt chart Table 1. r-404a pressure ­ temperature chart to determine s Mo99 p-t chart. Solved Surf. pressure: 1024hpa; surface temperature: -33.1 | Chegg.com. Rh temp tables nwcg dew point table psychometric bulb dry weather pressure 2 pts10jun2554 Chart pressure pt temperature pdffiller

more Freon™ MO99 ™ or Freon™ NU-22B in small amounts (still by transferring as liquid from the charging cylinder), until the system conditions reach the desired level. See the …An R-22 Refrigerant Replacement for Direct Expansion Refrigeration. Freon™ MO29 (R-422D) refrigerant is a low-toxicity, non-ozone depleting hydrofluorocarbon (HFC) replacement for R-22. Compatible with traditional and new lubricants, including mineral (MO), alkylbenzene (AB), and polyolester (POE) oils, most systems retrofitting to Freon ...Freon™ MO99 is the closest match to R-22 of all "no oil change" replacement refrigerants. It is compatible with all traditional and new lubricants. Compare MO99 to other R-22 replacement products. Freon™ MO99 matches R-22 in terms of capacity and efficiency in most systems, but with a significantly lower discharge temperature that may ...MO99 Retrofit guide. The low side pressure with MO99 will be a couple of psi lower than R-22 while the high side (cond) will be slightly higher than R-22. The MO99 retrofit guide has a lot of useful information, including proper setting of superheat and subcool. It seems 15°of SH and 5-7° SC would be adequate.Get the saturation number from the Refrigerant Slider APP by typing in the PSI reading on the High Side. Subtract high side pipe temp reading.R407c pt chartR448 refrigerant pt chart / pressure temperature chart for mo99 â Pressure r134a r22 refrigerant saturation 134a freon r410a r12 handypdf fillableR134a pressure temperature chart. R410a r407a vaporReady to convert from r12 to r134a Famous r134a pressure chartPressure chart temperature printable pdf.Temperature-Pressure Chart for Common Refrigerants. Download PDF Version: PT Chart for common refrigerantsmore Freon™ MO99 ™ or Freon™ NU-22B in small amounts (still by transferring as liquid from the charging cylinder), until the system conditions reach the desired level. See the pressure-temperature charts in this bulletin to compare pressures and temperatures, to calculate superheat or subcooling for the refrigerant.

R-452A XP44 Basic Info. R-452A is a newer refrigerant that falls into the Hydrofluoroolefins classification family (HFOs). It can also be found under the Opteon XP44 brand name from Chemours. It is a zeotropic blend of R-1234yf (30%), R-32 (11%), and R-125 (59%). This refrigerant was designed to be an alternative to the extremely high …R-409A R-409A R-401A R-401A R-401B R-401B R-12 R-134a Liquid Vapor Liquid Vapor Liquid Vapor Pressure Pressure Pressure Pressure Pressure Pressure. Sat. Temp (°F) Red Numerals - Inches Hg. Below 1 ATM. PRESSURE TEMPERATURE CHART. HIGH ELEVATION 5,000 FEET.DuPont® ISCEON® MO99™ (R-438A) Refrigerant ^ 25 Lb Disposable Cylinder ^ Can Be Used With Mineral Oil, Alkyl Benzene Or POE Oil ^ Non-Ozone Depleting ^ Do Not Mix Refrigerants ^ Voids All Manufacturers' Warranties ^ Does Not Require Equipment Change ^ Eliminates Disruptive Oil Changes ^ Minimizes Time Spent On Control Set Point …R22 Pressure-Temperature Chart-49-45: 1-17.2 51: 10.6 101: 38.3-48-44.4 2-16.7 52; 11.1 102; ... Saturation Pressure-Temperature Data for R22 (psig)* Temp (°F ...

Regions bank routing number arkansas.

Freon™ MO99 Refrigerant R-421A (Choice™) vs. Freon™ MO99 • R-421A capacity is 12% lower than R-22, an additional 5% lower than MO99. • Mass flow rate of R-421A is >20% higher than R-22, an additional ~10% higher than MO99. • R-421A is a pure HFC blend with a small amount of lubricant in the cylinder.Pressure Temperature Charts Vapor Pressure in PSIG °F °C R-449A Liquid R-449A Vapor 60 15.6 128 108 65 18.3 140 118 70 21.1 152 129 75 23.9 165 141 80 26.7 179 154 85 29.4 193 167 90 32.2 208 182 95 35.0 224 197 100 37.8 241 213 105 40.6 259 229 110 43.3 278 247 115 46.1 297 266 120 48.9 318 286 125 51.7 339 307 130 54.4 362 329 135 57.2 385 352 140 60.0 410 376 145 62.8 435 402 150 65.6 462 429Relationship Between Tc-99m and Mo-99 in the Generator at Various Times after Elution. The ratio of Tc-99m to Mo-99 used in the above table was calculated using the equation: Yield Charts Available from Manufacturers: Limit = 0.15 µCi Mo-99 per 1 mCi Tc-99m at time of administration. Calculations and a chart of Tc-99m expiration times based on ...A Versatile Replacement for Common R-12 Service Blends. Freon™ MO49Plus (R-437A) refrigerant was created as a hydrofluorocarbon (HFC) retrofit for service blends like R-101A, R-401B, and R-409A that contain hydrochlorofluorocarbon (HCFC) components. Freon™ MO49Plus provides a quick, cost-effective way to retrofit existing R-12 and R-500 ...

Fact checked by Maddy Simpson. Print. Prothrombin time (PT) and partial thromboplastin time (PTT) are tests used to evaluate coagulation, or the clotting of blood. While both measure how quickly blood clots, they have distinct purposes: The PT test, also known as the PT/INR test, looks at the extrinsic pathway of coagulation (meaning ...85% Freon™ MO99™ or NU-22B™ of the assumed proper charge size. The final charge amount will vary by system, but will be approximately the same weight as with R-22. 8. Start up system. Monitor pressures, subcooling, and superheat while referencing the Freon™ MO99™ or NU-22B™ PT chart. IfThe Freon™ MO99 P/T chart and additional technical information is available at freon.com. In addition, there is a No. Freon™ MO99 has an A1 refrigerant safety free mobile "PT Calculator" app for Apple® and Android® classification designating nonflammability and low toxicity devices that contains P/T conversions and basic product under ...Get the saturation number from the Refrigerant Slider APP by typing in the PSI reading on the High Side. Subtract high side pipe temp reading.Pressure Temperature Chart mation on one of the leaders in refrigerants and how we can help you, visit forane.com. PRESSURE (PSIG)* PRESSURE (PSIG)* Sat Temp (°F) R-22 R-32 R-123 R-134a R-401A Liquid Pressure R-401A Vapor Pressure R-401B Liquid Pressure R-401B Vapor Pressure-50 6.1 5.2 29.2 18.7 13.5 17.9 12.2 16.8If you have an old Air conditioning system that uses R22 refrigerant and you want to replace the refrigerant with a non-ozone depleting option, R438A would be an excellent choice. The refrigerant is a HFC blend consisting of five components. They include 8.5% of R32, 45% of R125, 44.2% of R134A, 1.7% of Butane (R600A), and 0.6% of …Download Mo99 Pt Chart Mp3 R-22 Conversion to R-438A M099, Reading Pressures, Adding Refrigerant, & Disconnect In this HVACR Training Video, We Show what is done to Retrofit an Existing R-22 Air Conditioning System to R438A/M099.Up to 10% lower capacity. Lubricant Recommendation: Compatible with mineral and alkylbenzene oil and if oil return becomes a concern, addition of polyolester lubricant in 5% increments could help resolve the issue. Retrofitting to: R-422B for R-22 Air Conditioning page 95. R-422B for R-22 Refrigeration page 95.

ISCEON® MO99™ provides similar cooling capacity and energy efficiency to R-22 in most systems, while operating at lower compressor discharge temperature. Actual performance depends on system design and operating conditions. Systems using ISCEON® MO99™ are easy to service. For most systems. ISCEON® MO99™ can be topped off during

R407C Pressure-Temperature Chart. Hello readers welcome to the new post. Here we will learn R407C Pressure-Temperature Chart. R410 refrigerant is a very famous refrigerant solution used for air conditioning systems. It is a mixture of hydrofluorocarbons and is employed as a refrigerant. it is an azeotropic blend of difluoromethane (R-32 ...Or download onto your own device. P-T Calculator. This comprehensive Pressure/Temperature calculation tool provides several unique features designed to make the HVAC/R technician’s job easier. Available for iOS and Android devices: For more information, call 800-262-0012. or e-mail [email protected] pressure-temperature (PT) chart is a valuable tool that service technicians use to check proper system operation. PT charts are most often used for three purposes: to set a coil pressure so that the refrigerant produces the desired temperature; to check the amount of superheat above the saturated vapor condition at the outlet of the evaporator and to …DuPont ISCEON MO99, also known as R-438A, is an environmentally friendly alternative to the original hydrochlorofluorocarbons (HCFCs) R-22 refrigerant. However, the advantages of MO99 span more than just environmental goals. Below are 10 reasons Dupont MO99 is the best R-22 replacement option. Refrigerant Depot is a …Jul 25, 2012 · Mississippi Gulf Coast. Posts. 56. Post Likes. The company that I work for has been using R438A since its introduction. We have used it in retrofits for supermarket rack systems. In addition, new small hp refrigeration (low and medium temp), CW and DX AC systems from 3 to over 100 tons.Pressure Temperature Chart - Realcold . SHOW MORE . SHOW LESS ... MO49 MO59 MO79 MO99 CO<br /> R134A R406A R22 R407C R410A R404A R507A<br />Mo99 p-t chartR22 to r134 conversion. here goes, all factory Patent ep0629229b1Pt chart r22 r-410a laminated pocket aid pressure / temperature # 34. Check Details Chart pressure temperature refrigerant r134a hvac air ac low r22 high blows refrigeration refrigerants quotes warm compressor sideMO99 Retrofit guide. The low side pressure with MO99 will be a couple of psi lower than R-22 while the high side (cond) will be slightly higher than R-22. The MO99 retrofit guide has a lot of useful information, including proper setting of superheat and subcool. It seems 15°of SH and 5-7° SC would be adequate.

Eureka mt zillow.

Iready scale score placement tables 2023.

Mo99 p-t chartR22 to r134 conversion. here goes, all factory Patent ep0629229b1Pt chart r22 r-410a laminated pocket aid pressure / temperature # 34. Check Details Chart pressure temperature refrigerant r134a hvac air ac low r22 high blows refrigeration refrigerants quotes warm compressor sideMolybdenum Mo99 decays to Technetium Tc 99m with a Molybdenum Mo99 half-life of 66 hours. This means that only 78% of the activity remains after 24 hours; 60% remains after 48 hours, etc. (see Table 3). All units have a minimum of 38 mm, 1.5 inches. (~ 6 half-value layers) of lead surrounding the activity.An R-22 Refrigerant Replacement for Direct Expansion Refrigeration. Freon™ MO29 (R-422D) refrigerant is a low-toxicity, non-ozone depleting hydrofluorocarbon (HFC) replacement for R-22. Compatible with traditional and new lubricants, including mineral (MO), alkylbenzene (AB), and polyolester (POE) oils, most systems retrofitting to Freon ...liquid temperature. In field service, where a Pressure- Temperature chart may contain only the saturated vapor or the saturated liquid temperature, the average condenser temperature can be more easily calculated by either subtracting 1 °F from the saturated vapor temperature or adding 1 °F to the saturated liquid temperature.Mo99 . I would like a few opinions about m099 as a replacement for r22.... 20 year old unit for a friend. Should I use it to get him by for another year or so? Edit... I work commercial and normally replace commercial units based on cost effective of r22 ... R421a no oil change, and almost identical pt chart Reply Sme11y1 ...Freon™ MO99 provides similar cooling capacity and energy efficiency to R-22 in most systems, while operating at a lower compressor discharge temperature. Actual performance depends on system design and operating conditions. Systems using Freon™ MO99 are easy to service. Freon™ MO99 can be topped off during service, without the needPT Charts For Refrigeration. Solstice® N40 (R-448A) and Solstice N13 (R-450A) are Honeywell's newest blends for commercial refrigeration. R-448A & R-407F are great retrofit options for R-22, R-404A, R-507, R-402A, & R-408A. Scan to learn more about our new PT Chart. Scan to learn more about calculating Glide. Pressure (psig)R404 Refrigerant Pressure Temperature Chart. R22 Refrigerant Pressure Temperature Chart. Pressure Temp Chart R-11, R-12, R-22, R123, R134A, R404A, R-500, R502. Using an HVAC refrigerant pressure temperature chart is necessary to be sure a unit is operating correctly. Below are three free pressure temperature charts that can be used to ... ….

Freon™ MO99 provides similar cooling capacity and energy efficiency to R-22 in most systems, while operating at a lower compressor discharge temperature. Actual performance depends on system design and operating conditions. Systems using Freon™ MO99 are easy to service. Freon™ MO99 can be topped off during service, without the needSuperheat/subcool - didn't have a mo99 pt chart handy. It had a txv. Now that I look..two different pt charts give me two different temperatures? ... I used the dew point column on the pt chart for checking the saturated suction temperature on mo99...and 75PSIG was 49 degrees. Reply . 08-22-2020, 09:37 AM #20. behappy. View Profile View Forum PostsR22 Refrigerant Pressure Temperature Chart. Pressure Temp Chart R-11, R-12, R-22, R123, R134A, R404A, R-500, R502. Using an HVAC refrigerant pressure temperature chart is necessary to be sure a unit is operating correctly. Below are three free pressure temperature charts that can be used to troubleshoot an HVAC unit.Freon™ MO99 (R-438A) Refrigerant Version 5.11 Revision Date: 11.10.2020 SDS Number: 1332344-00045 Date of last issue: 27.02.2020 Date of first issue: 27.02.2017 2 / 21 Misuse or intentional inhalation abuse may cause death without warning symptoms, due to cardi-ac effects. Rapid evaporation of the product may cause frostbite.What is MO99 Refrigerant? MO99 refrigerant is a refrigerant designed and patented by the DuPont, or now Chemours, Chemical company. This refrigerant is designed to be a drop in R-22 replacement. The best thing about this type of refrigerant and the reason you hear it brought up all the time when looking for R-22 replacement … Read moreDecay Calculator. This Web application will allow you to calculate the activity of a radionuclide after a specified interval of time. The list of radionuclides excludes those with half lives measured in seconds.Mo99 P-t Chart Check Details Trace carboniferous ppm concentrations wt. Refrigerant r 23 hfc23 chf3 gas used in very low temperaturePrintable refrigerant pt chart Rr per 10 ug/m 3 increase of daily averages of pm10, pm2.5, so2Granitoids wt ppm uplift. File 7 2007118114423-0Major (wt %) and trace (ppm) elements in the granitoids of the R448 ...Refrigerant Pressure - Temperature Chart. Pressure values are displayed for R-22, R-410a, R-407c, R-134a and R-404a refrigerants. Items Displayed in Red shows pressure in inches of Mercury. Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information.Manufacturers of refrigerants, controls, and other suppliers distribute hundreds of thousands of pressure-temperature charts to the trade every year. It would be rare indeed to find service technicians who could not put their hands on a pressure-temperature (P-T) card at a minute's notice. In spite of the widespread availability and apparent reference to the pressure-temperature relationship ... Pt chart for mo99, These charts serve as indispensable references for HVAC technicians and engineers working with cooling systems. Understanding the Components of a PT Chart: A typical PT chart consists of several components, including: Pressure Scale: The vertical axis represents pressure, often measured in units like pounds per square inch (psi) or …, Gantt charts can be versatile tools for project management when used correctly. However, if you’re part of an organization that regularly uses them, you’re also probably aware that..., R-404A History. R-404A rose to prominence in the late 1990’s with the phasing out of CFC and HCFC refrigerants like R-12 and R-502. There had to be a replacement for the Ozone damaging refrigerants of the past and the successor was the HFC R-404A that we all know of today. 404A’s reign however was short lived., Temperature-Pressure Chart for Common Refrigerants Temperature R404A R407C R438A (ISCEON® MO99) R410A. 18 436 937 925 1268 1264 879 727 819 696 961 692 183 703 5364 457 300 20 470 996 983 1346 1342 936 779 873 746 1021 735 201 756 5628 490 326 22 507 1057 1044 1428 1423 996 833 928 797 1083 780 220 812 5902 526 354, We also offer competitive prices if you want to purchase bulk refrigerants and get wholesale prices and fastest delivery. Show entries. Refrigerant. Price. R134-30 AUTO. 339.9. R134-30 UV DYE. 349.9., Cooking meat can be a tricky task, especially if you don’t know the basics. Fortunately, there are meat cooking charts that can help you get the job done right. In this article, we..., R22 r134 R22 chart 1 Patent ep0629229b1. R32 refrigerant r23 r125 patents google r502 r22 r12 r11 mixture azeotropic non claims. R22 to r134 conversion. here goes, all factoryAir conditioner pressure chart r22 R22 conversionPt chart r22 r-410a laminated pocket aid pressure / temperature # 34., A Versatile Replacement for Common R-12 Service Blends. Freon™ MO49Plus (R-437A) refrigerant was created as a hydrofluorocarbon (HFC) retrofit for service blends like R-101A, R-401B, and R-409A that contain hydrochlorofluorocarbon (HCFC) components. Freon™ MO49Plus provides a quick, cost-effective way to retrofit existing R-12 and R-500 ..., HVAC PT Chart. Our PT refrigerant chart supports over 100 refrigerants.. Set atmospheric pressure to absolute or set to guage and then change the default 14.7 ATM Press to your desired setting; all from the measurements/unit tab., rsl the refrigerant specalists ⭐⭐⭐⭐⭐ Huawei 63 unbiased r404 pressure temperature chart. 53 efficient r22 temperature chart. mo99 pt chart fortunewheels co. pt chart r11 r410a pt chart pdf r22 charge chart r502 pt., A Cost-Effective R-22 Retrofit Refrigerant for AC and Refrigeration. Freon™ MO59 (R-417A) refrigerant is a hydrofluorocarbon (HFC) retrofit alternative for R-22 in direct expansion (DX) stationary air conditioning (AC) and medium-temperature commercial refrigeration systems. Because Freon™ MO59 is compatible with mineral (MO), alkylbenzene ..., Keep in mind that ideally the orifice should be replaced with a slightly larger one when changing to either MO99(R-438A), or R-422D, on fixed metered systems. ... First thing I'd want to know is if you're using the right pt chart. Glides in dew and bubble points have to be accounted for. Reply . 04-14-2017, 11:05 PM #14. Mark s. View Profile ..., 8 Retrofit Guidelines for DuPont™ ISCEON®MO29 Refrigerant. Retrofit Check List: 2) Retrofit Progress Checks. Retrofit Steps 1 Recover old refrigerant using good refrigeration practice. Use dedicated recovery cylinder(s) Weigh the recovered refrigerant De-gas the compressor oil using a vacuum pump., Forane 407C Pressure Temperature Chart Forane 407C, R-407C, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas ..., more Freon™ MO99 ™ or Freon™ NU-22B in small amounts (still by transferring as liquid from the charging cylinder), until the system conditions reach the desired level. See the pressure-temperature charts in this bulletin to compare pressures and temperatures, to calculate superheat or subcooling for the refrigerant., PRESSURE TEMPERATURE CHART - URI.com www.uri.com. PRESSURE TEMPERATURE CHART 0536-0537_Refrigerants_URI18.qxp 2/13/2018 1:10 PM Page 536. TABLE OF CONTENTS REFRIGERANTS & LUBRICANTS 537 REFRIGERANTS & LUBRICANTS ... It can replace R22, R417A and R407C with existing oil in system High Ambient and Centrifugal Chillers R-124 100 A1 0 MINERAL OIL or ALKYLBENZENE, attachment 2—fitness assessment charts 54 attachment 3—fitness assessment verbal instructions 64 attachment 4—altitude time correction for 1.5 mile run and 2.0 kilometer walk 67 attachment 5—written order for fitness assessment cell (fac) augmentees 69 attachment 6—sample memorandum for tdy or pme 70, Refrigerating Engineers & Technicians Association. Toll Free: 844.801.3711. Phone: 541.497.2955. Fax: 541.497.2966. 1725 Ferry St SW, Albany, OR 97322, chemours pt calc on the app store ⭐⭐⭐⭐⭐ Huawei subcooling and superheat superheroes of system charging. check the refrigerant charge in superheat step by step. subcooling and superheat superheroes of system charging. 42 punctual pressure chart for r22., In this series from Chadwell Supply and Chadwell University's Vann Flippen, walk through the refrigerants available to replace R22 and understand the pros an..., Mississippi Gulf Coast. Posts. 56. Post Likes. The company that I work for has been using R438A since its introduction. We have used it in retrofits for supermarket rack systems. In addition, new small hp refrigeration (low and medium temp), CW and DX AC systems from 3 to over 100 tons., An Excellent Replacement for R-22, R-404A, and R-507 Refrigerants. Freon™ 407A (R-407A) refrigerant is a reliable, stable, and nonflammable option for low- and medium-temperature refrigeration systems. This non-ozone depleting, hydrofluorocarbon (HFC) refrigerant is a replacement for R-22 and provides a lower global warming potential (GWP ..., Dec 18, 2023 · Mo99 P-t Chart 18 Dec 2023. Mo99 p-t chart Representative major (wt %), trace element (ppm) concentrations for the R134a pressure temperature chart for automotive. R22 P-t Chart Low Side. The "official" monoprice monolith htp-1 owners thread 134a pressure r134a refrigerant furthermore conditioners Mo99 p-t chart, Temperature Pressure Chart (EN) Embraco Cross Ref (EN) ... Application Table - Rotary (PT) (ES) Catalog - Fractionary 50 Hz (ES) Catalog - AE2 - Asia Pacific (EN), Browse a directory of organizations that use MyChart. Sign up or login., 42 punctual pressure chart for r22 ⭐⭐⭐⭐⭐ Huawei r 22 conversion to r 438a m099 reading pressures adding refrigerant disconnect. 11 bright r134a static pressure temperature chart. how to use a p t chart. subcooling and superheat pdf download., A/C & High Temperature. 45°F evaporator 115°F condenser 65°F return gas with 15°F subcooling Discharge Temperature, °F -22 -45 -31 Discharge Pressure, psi +3 +6 +5. + is increase and - is decrease for ISCEON®MO99™vs R-22 *R-22 assumes demand cooling with low temp discharge temperature of 275°F., For system-specific guidance on working with HFC blends in "semi-flooded" operations with low-pressure receivers, contact DuPont or consult the OEM. Easy Steps to Retrofit. The following provides a summary of the basic retrofit steps for ISCEON® MO99TM. (Detailed discussion of each step is provided in this bulletin.), • When comparing R-22 with replacement blends, pressure-temperature chart comparisons are not the best indicators of performance. It is critical to look at suction and discharge pressure ... • R-422D capacity is 8% lower than R-22, similar to MO99. • Mass flow rate of R-422D is >30% higher than R-22, an additional 20% higher than MO99., more Freon™ MO99 ™ or Freon™ NU-22B in small amounts (still by transferring as liquid from the charging cylinder), until the system conditions reach the desired level. See the pressure-temperature charts in this bulletin to compare pressures and temperatures, to calculate superheat or subcooling for the refrigerant., R22 pressure temperature chart. Tsp 999th pm10 readings pm2Pt chart 134a Granitoids wt ppm upliftMo99 p-t chart. R448 refrigerant pt chart / pressure temperature chart for mo99 âMajor (wt %) and trace (ppm) element analysis of the tourmaline samples Major, minor (wt%) and trace element (ppm) data of composite boreholeMedian (50th) and 90th and ..., PT-100 Resistance/Ohms Chart °C (t90) 0 1 2 3 4 5 6 7 8 9 °C (t90) -200 18.52-200 -190 22.83 22.4 21.97 21.54 21.11 20.68 20.25 19.82 19.38 18.95-190 -180 27.1 26. ..., Pt Chart For Mo99 - I replaced a 3.5 ton york r22 condenser with a 3.5 ton r22 rheem. Freon™ mo99™ has compatibility with all traditional and new lubricants,. Traditional pt charts list the saturated refrigerant pressure, in psig, with a column for temperature down the left side.