Cleaning & Sterilization Guidelines. Cleaning & Sterilization Guidelines for Synthes Trauma, CMF, Biomaterials and Spine Devices.

Synthes pelvic inventory. 4 Synthes LCP Proximal Femoral Plate 4.5/5.0 Technique Guide Anatomic reduction Anatomic plate profile assists reduction of metaphysis to diaphysis and facilitates restoration of the neck-shaft angle by proper screw placement. Stable fixation The combination of conventional and locking plate fixation offers optimum fixation irrespective of bone ...

The SKYLINE™ Anterior Cervical Plate System provides a versatile system of implants and instruments to accommodate the needs and individual preferences of surgeons. The SKYLINE Anterior Cervical Plate System is designed for use in a variable, constrained, or hybrid screw configuration. Contact Us.

The Mini External Fixator is made up of the following key components: Holding clamps available in 2 sizes. 3.0 mm / 3.0 mm and 3.0 mm / 4.0 mm connecting clamps. Threaded, trocar tip Kirschner wires available in 2 sizes. Angled connecting bar.3.5 mm Low Profile Pelvic System. Ouch! Your graphics card does not support WebGL. Find out how to fix it here. Please refer to the instructions for use for a complete list of indications, contraindications, warnings and precautions. visualized by pixelmolkerei.ch. Interactive 3D Web application by pixelmolkerei.Focusing on the instrumentation surrounding exposure and reduction for pelvis and acetabulum fractures, PRO Pelvis plating system is uniquely designed to facilitate the …Pawn shops have long been a popular option for people looking to buy or sell items at affordable prices. However, one common challenge with traditional pawn shops is the limited vi...Nail for Pelvic C-Clamp, cannulated, Stainless Steel Article No. Length (mm) 02.306.006 190 02.306.007 210 Steinmann Pin, Stainless Steel Article No. B (mm) Length (mm) 293.000.302150 3.0 293.000.352200 3.5 ... Synthes External Fixation and Distraction Systems consists of various implants including Schanz Screws (self-tapping, self-drilling …1 DePuy Synthes 6.5 mm and 7.3 mm Cannulated Screws Surgical Technique. Percutaneous Technique 4. Insert screw Instruments 310.495 7.3 mm Cannulated Drill Bit 310.63 5.0 mm Cannulated Drill Bit 314.05 Cannulated Hexagonal Screwdriver 314.11 Holding Sleeve

Mortality. Constantini et al J Trauma Acute Care Surg 2016. - multi-centred prospective study of 1339 patients with pelvic fractures at Level 1 trauma centers. - overall mortality 9%. - pelvic trauma with shock has 30% mortality. Dente et al Am J Surg 2005. - 44 open pelvic fractures. - overall mortality 45%. - concurrent intra-abdominal injury ...The Angular Stable Locking System (ASLS) provides angular and axial stability for screws used in combination with an intramedullary nail in the fixation of fractures. Provides improved stiffness and decreased interfragmentary movement compared to conventional locking. 1-3. Product Specifications. How to Use This Product.DESCRIPTION. The LCP™ Locking Attachment Plate offers an alternative to cerclage cables and uses a connecting screw to augment the stabilization of fractures. The locking capability stabilizes fixed-angle constructs in periprosthetic fractures, and fractures in the presence of intramedullary implants. Product Specifications.DePuy Synthes 2.7 mm variable angle locking calcaneal plating system.pdf. DePuy synthes vet mini fragment system.pdf. Synthes screw reference chart.pdf. DePuy Synthes modular hand system.pdf. Synthes External Fixation system.pdf. Synthes Small Fragment Instrument and Implant Set with Self-Tapping Screws 105.408.pdf. Synthes Maxillofacial Micro ...Abstract. Since the modern principles were laid down by Letournel and Judet, acetabular fracture surgery has been rapidly evolving. From early attempts of fixation using wires to the emergence of 3D printed plates, this chapter aims to highlight the different plate designs used for pelvis and acetabular fracture surgery.Inventory Control Form 4.5 mm VA LCPTM Curved Condylar Plate System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. SS/VALCPCC/ICF/V2 04/22 Page 1 of 2 To order (USA): 800-523-0322

What makes that synthes pelvic implant set inventory rule form legally valid? As which fellowship ditches in-office working pricing, which finalize of documents increasingly occurs online. The synthes lower project pelvic inventory isn’t an exception. Dealing with to using digital utility is differently from doing so in the physical world.Choose your Location. Last Updated Jun 1, 2023. From this site you can view or print Instructions For Use for DePuy Synthes devices. Manuals should be reviewed before using or implanting a device, or performing follow-up care.Low Profile 3.5mm Pelvic System. The 3.5mm Low Profile Pelvic implants are intended for temporary fixation, correction or stabilization of bones in the pelvis. 1. Get in Touch with a Sales Consultant.State. Zip code. 1. PRO-WP-1. Focusing on the instrumentation surrounding exposure and reduction for pelvis and acetabulum fractures, PRO Pelvis plating system is uniquely designed to facilitate the Anterior Intrapelvic Approach (AIP), where working in the deep, narrow space in the pelvis poses special surgical challenges.Variable Angle LCP™ Proximal Tibia Plate (3.5 mm) 02.211.201, 02.211.201S, 02.211.202... Part of the Periarticular Plating System which merges variable angle locking screw technology with conventional plating techniques, this plate provides a fixed-angle construct while allowing surgeons the freedom to choose the screw trajectory before ...

How to remove scientific notation in calculator ti 84.

The DePuy Synthes Large External Fixation Systems are intended to provide treatment for long bone and pelvic fractures that require external fixation. Specifically, the components can be used for: • Stabilization of soft tissues and fractures • Polytrauma/multiple orthopaedic trauma • Vertically stable pelvic fractures, or as a treatment ...Quick steps to complete and e-sign Synthes Low profile pelvic inventory online: Use Get Form or simply click on the template preview to open it in the editor. Start completing the fillable fields and carefully type in required information. Use the Cross or Check marks in the top toolbar to select your answers in the list boxes.Abnormal pelvic tilt, according to the company, affects about 20% of patients who require total hip arthroplasty, and 485 of hip revisions are due to suboptimal cup positioning because of pelvic tilt. CUPTIMIZE enhances DePuy Synthes VELYS hip navigation's intra-operative capabilities to allow more personalized care.In this study the AO Pelvic C-Clamp (SYNTHES, Oberdorf, Switzerland) was placed on an anatomic pelvic model (SYNBONE 4201.1 Pelvic Trainer; Synbone, Malans, Switzerland) (Fig. 1), specifically developed by pelvic trauma experts for training purposes. Download : Download high-res image (326KB)LCP™ Ulna Osteotomy System (2.7 mm) 02.111.900, 02.111.900S, 02.111.901... The LCP™ Ulna Osteotomy System is a comprehensive system of plates allowing for ulnar shortening osteotomies. The system provides a low profile, angular stable fixation with a choice of two cut styles: transverse (90°) and oblique (45°).Inventory Control Form Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada Please contact your sales consultant for items approved for sale in Canada. *2.4 mm Cortex Screws in lengths 42-60 mm are available in the 2.4/2.7 mm VA-LCP Forefoot/Midfoot Plating System.

• DePuy Synthes recommends predrilling in dense bone when using 5 mm or 6 mm screws. Drill speed rate should never exceed 1,800 rpm, particularly in dense, hard bone. Higher drill speed rate can result in thermal necrosis of the bone, soft tissue burns, and an oversized hole to be drilled. The adverse effects of an oversizedFind your exact synthes low profile pelvic inventory for free on the web! Try our advanced editing features to customize your form. Edit existing text and fill in PDF templates with ease!Inventory Control Form Variable Angle LCP Distal Radius Plates Drill Bits 310.19 2.0 mm, quick coupling, 100 mm 202.882 310.26 2.7 mm, quick coupling, 100 mm 310.509 1.8 mm with depth mark, quick coupling, 110 mm 202.874 310.530202.886 2.4 mm, quick coupling, 100 mm 1.8 mm Variable Angle Locking Buttress Pins, with T8 STARDRIVE Recess LengthThe MatrixRIB™ Fixation System offers stable fixation of normal and osteoporotic ribs combined with minimally invasive technique. The system consists of precontoured locking plates, locking screws, intramedullary splints, and custom instruments for the fixation and stabilization of the chest wall. 1. Get in Touch with a Sales Consultant.PFDI- 20 Instructions: Please answer all of the questions in the following survey. These questions will ask you if you have certain bowel, bladder, or pelvic symptoms and, if you do, how much they bother you. Answer these by circling the appropriate number. While answering these questions, please consider your symptoms over the last 3 months.MultiLoc™ Humeral Nail. EXPERT™ Humeral Nailing System. Diameters Available. Short Nails - 8 mm & 9.5 mm; Long Nails - 7 m and 8.5 mm. 7, 9, 11 mm. Length Available. 160 mm (Short Nail);180-315 mm (Long Nails) 150 mm (Short Nail);190-320 mm (Long Nails) Radius of Curvature.Inventory Control Form (Titanium) View PDF . Surgical Technique Guide Synthes/Limelight - 3.5 mm LCP® Superior Anterior Clavicle Plates . Select all documents (2)The LCP™ Proximal Femur Plate (4.5 mm) is part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. The stainless-steel plate features Combi holes, allowing fixation with locking or cortex screws. Product Specifications.

Inventory Control Form QIS AND 2.0 MM CANNULATED SCREW SYSTEM PLUS (CSS+) Head Height: 1.65 mm Washer and Head Construct Height: 1.44 mm Thread Length Short Thread: approx. 25% Total Length or 4 mm Long Thread: approx. 40% Total Length Thread Length Head Height Construct Height Length Washers Part Number 04.353.900.05 Washer For 2.0 Cann Screw ...

and Pelvic C-Clamp Cannulated Nails. Schanz Screws and Steinmann Pins can be used in various anatomical locations in the body based on the external fixation and distraction system being utilized. The Pelvic C-Clamp Cannulated Nails are only used in the pelvic ring. All external fixator implants are single packed. Schanz screws and Steinmann pinsInventory Control Form. Surgical Technique Guide - Modular Knee Bridge. Surgical Technique Guide - Pelvic Frame. Download Selected Items. © DePuy Synthes 2023. All Rights Reserved.DESCRIPTION. Our LCP™ Curved Locking Compression Plates are part of the DePuy Synthes Trauma LCP™ Locking Compression Plate System. This stainless steel and titanium plate screw system merges locking screw technology with conventional plating techniques for use in various orthopaedic trauma applications. Get in Touch with a Sales Consultant.Inventory Control Form Small Fragment Locking Compression Plate (LCP™) System 204.848 3.5 mm Locking Screws, self-tapping, with StarDrive™ Recess Length 202.830 30 mm 202.832202.812 32 mm 202.834 34 mm 202.816 202.836 36 mm 202.818 202.838 38 mm 202.840202.820 40 mm 202.845 45 mm 202.850 50 mm 202.826 202.855 55 mm Length 212.113 34 mm 212. ...The Low Profile 3.5 mm Pelvic System is intended for pelvic and acetabular reconstructive surgery. The reconstruction plates are also used for fracture fixation of the distal humerus, clavicle and scapula. It is comprised of four main elements: A range of new implants. Instruments for plate and screw fixation. Retraction instruments.Manuals and User Guides for Synthes Pelvic C-Clamp. We have 1 Synthes Pelvic C-Clamp manual available for free PDF download: Technique Manual . Synthes Pelvic C-Clamp Technique Manual (18 pages) Emergency Stabilization Instrument for Unstable Injuries and Fractures of the Pelvic Ring C-type Injuries. Brand: Synthes ...The DePuy Synthes 4.5mm VA-LCP Curved Condylar Plate System has been approved by the FDA for "buttressing multi-fragmentary distal femur fractures including: supracondylar, intra-articular and extra-articular condylar fractures, periprosthetic fractures, fractures in normal or osteopenic bone, and non-unions and malunions." ...Powered by a legacy of orthopaedic excellence, the DePuy Synthes Variable Angle LCP™ Periprosthetic Proximal Femur Plating System 3.5/4.5/5.0 aims to deliver the real strength and versatility needed by …The Titanium Cannulated Adolescent Lateral Entry Femoral Nail is an expert nailing system with radiolucent instrumentation. It includes: End Caps. Easy-to-use instrumentation facilitates the surgical procedure. Standard Locking Screws. 5 mm Recon Screws. Get in Touch with a Sales Consultant.Features & Benefits. LCP Combi-holes. Combi-holes in the shaft accept: 3.5 mm locking screws. 3.5 mm cortex screws. 4.0 mm cancellous bone screws. Multiple Screw Options. Five coaxial distal holes accept 2.4 mm and 2.7 mm locking and cortex screws to provide multiple screw options. Kirschner Holes.

Uniontown newspaper obituaries.

2015 ford f150 wheel torque specs.

Inventory Control Form LCP Dynamic Helical Hip System (DHHS) SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J5047-E 2/11 LCP DHHS Compression Screw 211.890 4.5 mm Cortex Screws, self-tapping LENGTH 214.828 28 …Inventory Control Form Variable Angle LCP Distal Radius Plates 2.4 mm VA LCP Dorsal Distal Radius Plate, Intermediate Column Shaft Holes Length (mm) Angled 02.115.630 3 41 +90° 02.115.631 3 41 –90° 02.115.640 4 49 +90° 02.115.641 4 49 –90° 2.4 mm VA LCP Dorsal Distal Radius L-Plate, 2 holes headWhat makes that synthes pelvic implant set inventory rule form legally valid? As which fellowship ditches in-office working pricing, which finalize of documents increasingly occurs online. The synthes lower project pelvic inventory isn’t an exception. Dealing with to using digital utility is differently from doing so in the physical world.Page 7: Technique Guide. The Pelvic C-Clamp set consists of the instruments and implants for the emergency treatment of the indicated fracture types. The bottom layer of the Vario Case houses the Pelvic C-Clamp and the optional pliers. The upper layer houses the cannulated nails in two lengths and the remaining instruments.According to the Center for Specialized Gynecology, pelvic cysts are fluid-filled pockets that form in the pelvic region, most often on the ovaries. Symptoms of pelvic and ovarian ...Synthes Large External Fixation is intended for use to provide treatment for long bone and pelvic fractures that require external fixation. Code Information: Part Number 390.007, Lot Number 6800599 ... The firm is requesting that you please examine your inventory for products with the above Part and Lot number and remove them. Call Synthes at 1 ...The Variable Angle LCP™ Curved Condylar Plate is a distal femur implant designed to address multiple patient anatomies, fracture patterns and surgical situations including supracondylar, intra-articular and extra-articular condylar fractures, and periprosthetic fractures. Product Specifications. How to Use This Product.Follow this step-by-step guide to build your Synthes inventory control form: Open the preferred template. Use the toolbar to adjust the form to your preferences. Fill out the form providing accurate details. Click on the signature field and add your eSignature. Send the document for signature to other signers if necessary.The modular set for pelvic implants. The design of the plates has been modified to allow easier contouring to the patients anatomy, together with optimized screw hole geometry for a wider range of angulations. The completely redesigned pelvic C-clamp comes in a set for emergency pelvic stabilization ready to use out of the box. A new Modular ...6 DePuy Synthes Large Distractor–Femur Surgical Technique Universal Joint Assembly 1 Select a 14.0 mm threaded spindle (A) of appropriate length (most likely 480 mm). A transverse hole will be in the proximal end when applied to the femur. 2 Turn the end piece with double joint (B) onto the threaded ….

Synthes 13 Sterilization Parameters for Set (115.700) This Synthes set with all additionally available items, as marked in the case, can be sterilized by the following parameters. For more information, please refer to graphic case package insert. Method Cycle Temperature Exposure Time Steam Prevacuum 132°–135°C 8 Minutes (Wrapped) (270 ...The EMAX™ 2 Plus System is the ultimate high-powered, lightweight 1,2, small bone cutting system. Designed for surgeon comfort, this lightweight 1,2 device gives surgeons the flexibility 1,3,7, power, and low noise they need for long, complex neurosurgery and spinal procedures. MIDAS REX MR7 High-Speed Drill System (Medtronic)Inventory Control Form 2.7 mm Variable Angle LCP® Clavicle Plate System 2.7 mm VA LCP Clavicle Plates Lateral Stainless Steel Titanium Plate Size Left/Right 02.112.61004.112.610 Left CS1 02.112.61104.112.611 Right CS1 02.112.61204.112.612 Left CS2 02.112.61304.112.613 Right CS2 02.112.61404.112.614 Left CS3 02.112.61504.112.615 Right CS3ITS pelvic reconstruction system, pure titanium ASTM F 136). The Matta Stryker pelvic plates offer annealed or nonannealed versions depending on the desired construct stiffness. If a less stiff construct is required such as in an ilium fracture or a posterior wall fracture, the annealed MPS flex plate can be used. Plate Designs and Function2.7 MM VA LCP™ CLAVICLE System. Product Codes: 02.112.610, 02.112.611, 02.112.612... View More. PRODUCT CODES. DESCRIPTION. Designed based on an analysis of clavicle CT scans to enhance plate-to-bone fit on a broad range of patients 1 and to treat lateral, shaft and medial fractures for small, medium and large clavicles.2 DePuy Synthes 3.5 mm LCP® Olecranon Plates Surgical Technique 3.5 mm LCP Olecranon Plates. Part of the DePuy Synthes locking compression plate (LCP) System. Features - Anatomically precontoured - Left and right plates - Head holes accept 3.5 mm locking screws, and 2.7 mm and 3.5 mm cortex screws - Shaft holes accept 3.5 mm locking2 Synthes LCP Proximal Tibial Plate 3.5 Technique Guide The LCP Proximal Tibial Plate 3.5 is part of the Small Frag-ment LCP System, which merges locking screw technology with conventional plating techniques. The LCP Proximal Tibial Plate 3.5 has a limited-contact profile. ... – Pelvic Implant Set, with self-tapping screws (for longerInventory Control Form MatrixRIB™ Fixation System Titanium MatrixRIB Pre-Contoured Plates Titanium MatrixRIB Intramedullary Splints 04.501.010 Small, 3 mm width 04.501.011 Medium, 4 mm width 04.501.012 Large, 5 mm width 04.501.001 15 holes for left rib number 3 04.501.002 15 holes for right rib number 3Synthes 13 Sterilization Parameters for Set (115.700) This Synthes set with all additionally available items, as marked in the case, can be sterilized by the following parameters. For more information, please refer to graphic case package insert. Method Cycle Temperature Exposure Time Steam Prevacuum 132°-135°C 8 Minutes (Wrapped) (270 ... Synthes pelvic inventory, The Synthes MatrixRIB intramedullary splints (04.501.010, 04.501.011, 04.501.012) and the universal plate (04.501.009) are indicated for the fixation and stabilization of ribs. Important: The Synthes MatrixRIB pre-contoured and straight plates are not intended for use as per-manent implants for bridging gaps after chest wall resections., A number of high-profile firms and startups have set up logistics networks in India in the last decade as they attempt to digitize neighborhood stores. Bangalore-headquartered star..., The Femoral Recon Nail System is an integrated nailing system designed to adapt to multiple surgical approaches. The FRN System provides the choice of Greater Trochanter (GT) and Piriformis Fossa (PF) entry points and anatomical nail designs to support surgical preferences and facilitate hospital standardization. Contact Us., 2 DePuy Synthes 3.5 mm LCP® Olecranon Plates Surgical Technique 3.5 mm LCP Olecranon Plates. Part of the DePuy Synthes locking compression plate (LCP) System. Features - Anatomically precontoured - Left and right plates - Head holes accept 3.5 mm locking screws, and 2.7 mm and 3.5 mm cortex screws - Shaft holes accept 3.5 mm locking, Variable Angle Locking Patella Plating System. The VA Locking Anterior Patella Plate 2.7 is designed to address different fracture patterns as per approved indication. The surgical technique guide includes two sections: Complex Fractures – 3-hole and 6-hole plates are recommended. Simple Fractures – Core, 3-hole, and 6-hole plates may be ..., Inventory Control Form LCP Clavicle Plate System Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J9001-D 10/10 3.5 mm LCP Superior Anterior Clavicle Plates, with Lateral Extension 3.5 mm LCP Superior Anterior Clavicle Plates HOLES HOLES, Features & Benefits. LCP Combi-holes. Combi-holes in the shaft accept: 3.5 mm locking screws. 3.5 mm cortex screws. 4.0 mm cancellous bone screws. Multiple Screw Options. Five coaxial distal holes accept 2.4 mm and 2.7 mm locking and cortex screws to provide multiple screw options. Kirschner Holes., Biodur 108 Alloy allows the Zimmer Cannulated System to feature large cannulation without compromising screw strength. The large cannulation accommodates a large/stiff guide wire. Guide wires are designed to increase strength and stiffness to help minimize skiving, deflecting, or "walking" on the bone. This aims to afford increase accuracy ..., The literature summarized in this document is literature known to DePuy Synthes at the time of this document release and may be incomplete. AO Foundation is a third party medically guided, not-for-profit organization led by an international group of surgeons specialized in the treatment of trauma and disorders of the musculoskeletal system., MatrixNEURO™ System. The MatrixNEURO™ System features regular (0.5 mm profile) and Ultra Low Profile (0.4 mm profile) implants. In addition, a variety of mesh options are available including various shapes and sizes, as well as contourable, reconstruction, and pre-formed. 1-3. Get In Touch with a Sales Consultant., External Fixator Devices include pins, wires, rods and clamps to form a frame for the reposition and fixation of bone fragments. Pins and wires are single-use im-plants and build the connection of the frame to the bone(s). Rods and clamps are the parts of the frame that are located outside of the body and are designed for multiple usages., Edit synthes low profile pelvic inventory form. Rearrange and rotate pages, insert new and alter existing texts, add new objects, and take advantage of other helpful tools. Click Done to apply changes and return to your Dashboard. Go to the Documents tab to access merging, splitting, locking, or unlocking functions., Inventory Control Form Date: Hospital: Titanium MatrixORTHOGNATHIC 1.85 mm Titanium Matrix Screws, self-drilling (dark purple) (1/pkg) 04.511.224.05 4 mm ... DEPUY SYNTHES CANADA To order: (800) 668-1119. Plates (cont'd) Titanium MatrixORTHOGNATHIC J9341-D 4/13 Inventory Control Form, 6 DePuy Synthes 6.5 mm and 7.3 mm Cannulated Screws Surgical Technique. Option 1a: Insert additional parallel guide wire(s) with adjustable parallel wire guide Use the 2.8 mm adjustable parallel wire guide to place parallel wires at various distances from the fi rst wire. Place the fi xed sleeve over the pre viously inserted wire and adjust the movable sleeve …, SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J3901-H 5/13 Inventory Control Form Titanium Cannulated Trochanteric Fixation Nail System Titanium Cannulated Trochanteric Fixation Nails, 10 mm distal diameter, sterile FEMORAL RIGHT LEFT ..., A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA., A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA., Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes "Import-ant ..., To fill out the SynForms DHS Inventory, follow these steps: 1. Obtain the SynForms DHS Inventory document from the appropriate source or download it from the designated platform. 2. Read the instructions provided with the form to understand the purpose and specific requirements of the inventory. 3., 4 DePuy Synthes 2.7 mm/3.5 mm LCP® Distal Fibula Plates Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which, DIAMETER LENGTH. 03.113.024 2.8 mm 250 mm, 95 mm calibration. 3.5 mm Variable Angle Locking Screws, Self-Tapping, T15 Stardrive. LENGTH LENGTH., The modular set for pelvic implants. The design of the plates has been modified to allow easier contouring to the patients anatomy, together with optimized screw hole geometry for a wider range of angulations. The completely redesigned pelvic C-clamp comes in a set for emergency pelvic stabilization ready to use out of the box. A new Modular ..., Inventory Control Form 2.7 mm Variable Angle LCP® Clavicle Plate System 2.7 mm VA LCP Clavicle Plates Lateral Stainless Steel Titanium Plate Size Left/Right 02.112.61004.112.610 Left CS1 02.112.61104.112.611 Right CS1 02.112.61204.112.612 Left CS2 02.112.61304.112.613 Right CS2 02.112.61404.112.614 Left CS3 02.112.61504.112.615 Right CS3, Pins, and Pelvic C-Clamp Cannulated Nails. Schanz Screws and Steinmann Pins can be used in various anatomical locations in the body based on the external fixation and distraction system being utilized. The Pelvic C-Clamp Cannulated Nails are only used in the pelvic ring. All external fixator implants are single packed. Schanz screws and ..., , Inventory Control Form Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada Please contact your sales consultant for items approved for sale in Canada. *2.4 mm Cortex Screws in lengths 42–60 mm are available in the 2.4/2.7 mm VA-LCP Forefoot/Midfoot Plating System., Craniomaxillofacial Distraction (CMFD) System. The modular CMFD system offers a low-profile stable distraction construct without unintentional reversal combined with intraoperative flexibility and ease-of-use during application and removal. 1-3. Anti-reversal detent clip is contained within distractor body for a consistent, smooth profile that ..., To order (Canada): 844-243-4321. Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. Titanium Patella Plates. Implants. Inventory Control Form. 2.7 mm VA Locking Patella Plating System. Stainless Steel (316L) Patella Plates 2.7 mm Variable Angle Locking Screws, Non-Sterile, (10-60 mm), Stainless Steel., Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10175-C 5/11 2.4 mm/2.7 mm VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm VA-LCP Forefoot/Midfoot Plating System 02.211.230 0° right 02.211.231 0° left 02.211.232 5 ..., DESCRIPTION. The LCP™ Locking Attachment Plate offers an alternative to cerclage cables and uses a connecting screw to augment the stabilization of fractures. The locking capability stabilizes fixed-angle constructs in periprosthetic fractures, and fractures in the presence of intramedullary implants. Product Specifications., Permits rapid reduction and stabilization of the posterior pelvic ring. Description The Pelvic C-Clamp is an emergency stablization instrument for unstable injuries and fractures of the pelvic ring. Unstable pelvic ring fractures can be associated with massive blood loss that can cause terminal shock. The Pelvic C-Clamp allows rapid reduction ..., synthes.vo.llnwd.net, The Synthes Large External Fixation System is intended to provide treatment for long bone and pelvic fractures that require external fixation. Specifically, the components can be used for: – Stabilization of soft tissues and fractures – Polytrauma/multiple orthopaedic trauma – Vertically stable pelvic fractures, or as a treatment adjunct