Tji sizes

Using TJI Span Tables The following screen shot comes from the Trus Joist TJI Manual. It shows the standard span tables for TJI’s. The tables look overwhelming but they are actually pretty simple to use. They are organized by two main tables, one for live load deflections of L/360 and one for L/480. Within each…

Tji sizes. Description: Featuring Trus Joist® TJI® Joists for Floor and Roof Applications. Document ID #: tj-4000. File Type: pdf. File Size: 5.1 MB. File Date: October 2023. Document Types: Design & Specification Categories. Engineered Lumber; Products. TJI® Joists

Backer Block(1) (Detail F1 5⁄8" or 3⁄4" 3⁄4" or 7⁄8" 7⁄8" or 1" net 2x6 2x8. or H2) (1) If necessary, increase filler and backer block height for face mount hangers and maintain 1⁄8" gap at top of joist. See detail W. Filler and backer block dimensions should accommodate required nailing without splitting.

Trus Joist® TJI® joists are a key part of making a high-performance floor. ... TJI Joists: Size: 11-7/8 in. Pro 230: Brand: Weyerhaeuser: Actual Size: 2-5/16 in. x 11-7/8 in. Application. Designed for use as a part of an engineered building system. Reviews. Write Your Own Review.What are LVL beam sizes. LVL beam (Laminated veneer lumber) sizes may vary as per manufacturer, but an LVL standard thickness (depth) are 1-3/4 inches to 3-1/2 inches thick and length of an LVL are generally available in 24′, 28′, 32′, 36′, 40′ and 44 feet with special order upto 60 Feet long.TJI® 210, 230, and 360 rim joist: One 16d (0.135" x 31⁄2") nail into each flange. With depths > 16", use TJI® 360 rim joist. TJI® 560 or 560D floor joist. TJI® 560 or 560D rim joist: Toenail with 10d (0.128" x 3") nails, one each side of TJI® joist flange. 13⁄4" minimum bearing.Floor panel nail, typically 8d (0.131" x 21⁄2") at 6" on-center. 11⁄4" TimberStrand® LSL rim board. Toe nail, 10d (0.131" x 3") at 6" on-center. Wall sheathing. 2x4 or 2x6 stud wall. When sheathing thickness exceeds 7⁄8", trim sheathing tongue at rim board. TJI® joist spanning in either direction.Software Solutions. Whether you are a design professional or lumber dealer, Weyerhaeuser offers an array of proprietary software to help you specify individual framing members, create cut lists, manage inventories—even help you design a complete structural frame. Learn more about our software. Technical Support.The two standard sizes of playing cards are the poker size and bridge size. Poker-sized playing cards are 2.5 inches wide by 3.5 inches long. Bridge-sized cards are 2.25 inches wid...

A pair of jeans labeled size 29 generally equates to a U.S. size 8 or 10, depending on the manufacturer. The 29 indicates a 29-inch waist size, but even this measurement is not alw...4", use 0.75 of the TJI® Joist header load. Top Flange Hangers: Use 10dx11⁄ 2” nails for all Top Flange hangers attached to an TJI® Joist header. See table for allowable loads. 1. See current Wood Construction Connectors catalog for Important Information and General Notes section and for hanger models, joist sizes,Installation Guide for Floor and Roof Framing with TJI 110, 210, 230, 360 and 560 Joists - tj-9001 ... File Size: 1.6 MB. File Date: September 2023. Document Types: Installation Categories. Engineered Lumber; OSB & Panels; Canada; Products. Microllam® LVL Beams; Microllam® LVL Headers;Size engineered wood, dimension lumber and steel in one tool – compare design results and select the most effective solution. Address field issues on site – use the joist and beam hole analysis or the TJI® notched flange analysis to determine if an issue at the jobsite will work without a modification.tj-9001 - Installation Guide for Floor and Roof Framing with TJI 110, 210, 230, 360 and 560 Joists; tj-9001p - Installation Guide for TJI 110, 210, 230, 360 and 560 Joists (in Punjabi language) tj-9001s - Guia de instalación para armazones de entrepisos y techos con viguetas TJI 110, 120, 230, 360 y 560

See page 28 for information on web stiffener sizes and nailing. EXAMPLE: Determine the stiffened end reaction capacity for a 14" LPI 32Plus with 2" of bearing for a non-snow roof load and supported on an SPF wall plate (425 psi). 1. …Our most versatile beam solution. tj-9001 - Installation Guide for Floor and Roof Framing with TJI 110, 210, 230, 360 and 560 Joists; tj-9001F - Guide D’installation Pour Ossature De Plancher Et De ToitureEngineered joists are also a little less stable (can't walk on them) until the sub-floor is installed. TJI's are available in many different sizes ranging from ...Document Library. Search for a document and use filters on the left to narrow by product or document type. Go to My Account to access your custom collections of documents and sharing instructions. Filter Results.In men’s shoes, a European size 39 is the equivalent of a size 5 to 5.5 in the United States. In women’s shoes, a European size 39 is the same as a women’s size 7.5 to 8.To change the size of pictures saved on your computer you need a photo-editing software. Photo-editing software allows you to make pictures larger or smaller, crop images or change...

Sean hannity salary 2022.

I am not sure you can clear span 28' with a 11 7/8 TGI but you could go with a larger size with no problem. ... TJI or other type I joists that ...Using TJI Span Tables The following screen shot comes from the Trus Joist TJI Manual. It shows the standard span tables for TJI’s. The tables look overwhelming but they are actually pretty simple to use. They are organized by two main tables, one for live load deflections of L/360 and one for L/480. Within each…Their dimensional stability helps resist the warping, twisting, and shrinking that can lead to squeaky floors. Because they are lightweight and come in long lengths, they're easier to install than traditional framing. TJI® joists come in different sizes for specific load/span needs.1.Using Table A, Table B, or both if required, determine the hole shape/size and select the TJI® joist and depth. 2. Scan horizontally until you intersect the correct hole size column. 3. Measurement shown is minimum distance from edge of hole to support. 4. Maintain the required minimum distance from the end and the intermediate or cantilever ...Other sizes may be available in Weyerhaeuser software; however, not all products are available in all markets. Contact your Weyerhaeuser representative for the sizes available in your area. This guide features the following Trus Joist® wall framing products: 1.3E TimberStrand ® LSL Studs: 1½" x 3½" (2x4) • 1½" x 5½" (2x6)TRUS-JOIST 2-1/2" x 14" TJI 230 Joist, by Linear Foot. 0 Reviews. Item: #2809-561. Model: #TJ-72002956. Product Overview Description. Our Return Policy If you are not completely satisfied with your purchase, in most cases, you can return it for a refund within 90 days. Lumber, Building Materials, Furniture and ...

European size. European (EU) and American (US) size symbols are two-digit numbers (eg 32, 36, 42), international letters are English abbreviations (UK) of words: S - small, M - medium, L - large. X - means "extra" appears before S, where XS means ("extra small") or before L (XL "extra large"), doubling X - increases or decreases the …Depending on the series you choose, TJI® joists are available in the following sizes: Flange Widths: 13⁄4", 21⁄16", 25⁄16", and 31⁄2" Depths: 91⁄2", 117⁄8", 14", and 16" Take the …Architectural Specifications. Follow. Spec Sheet for Trus Joist Products. Spec Sheet for TJI® Joists. Spec Sheet for TimberStrand® LSL. Spec Sheet for Microllam® LVL. Spec Sheet for Parallam® PSL. Spec Sheet for Parallam® Plus PSL.Refer to the hole chart on page 9 of the TJI® Specifiers Guide for uniformly loaded joists. Often, hole size can be increased and holes can be placed closer to bearing than shown on the chart based on actual design spans and loads. Use Forte®WEB single member sizing software to check hole sizes and locations or contact Weyerhaeuser Technical ...TJI Joists: Size and Span. One of the main advantages of using TJI joists is that they are available in different sizes. Weyerhaeuser provides TJI joists having depths of 9½”, 11 7⁄8″, 14″, 16″, 18″, 20″, 22″, and 24″ and flange widths of 1¾”, 21⁄16″, 25⁄16″, and 3½”.The TJI 110 offers a suitable alternative to 2×10 and 2×12 dimensional lumber. The TJI 220 is larger at 2-1/16” in width. It is identical to the TJI 230 in terms of depth availability. But the TJI 230 is 2-5/16” in width. The TJI 360 and TJI 560 have three depth options and a width of 2-5/16” and 3-1/2”, respectively.Here are the key components of a floor frame: Floor joist: Horizontal pieces or slats that hold up flooring materials. Header joist: Frames the opening of the floor. Blocking: Small blocks of lumber between joists that stabilize and brace the slats. Beam: Provides structure and supports the weight of a floor; made of lumber or steel.tj-9001 - Installation Guide for Floor and Roof Framing with TJI 110, 210, 230, 360 and 560 Joists; tj-9001F - Guide D’installation Pour Ossature De Plancher Et De Toiture; csg-tjus22 - Simpson Connector Guide for Trus …TJI® 210, 230, and 360 rim joist: One 16d (0.135" x 31⁄2") nail into each flange. With depths > 16", use TJI® 360 rim joist. TJI® 560 or 560D floor joist. TJI® 560 or 560D rim joist: Toenail with 10d (0.128" x 3") nails, one each side of TJI® joist flange. 13⁄4" minimum bearing.strength, stiffness and size than traditional lumber, providing a strong, sturdy floor. We offer longer lengths so that ceilings and floors can be designed with fewer pieces, saving time on installation. Other advantages over lumber include lower moisture content, which makes our I-Joists less likely to split, shrink, twist, warp or bow.TJI 110, 210, 230, 360, and 560 Joist Specifier's Guide. FLOOR SOLUTIONS. ROOF SOLUTIONS. TRUS JOIST® TJI® 110 . TJI®210. 230 . TJI®360 560 JOISTS. Floor® Joists for Applications. Predictable. Significantly Reduces Callbacks. Available in Long Lengths. Limited Product Warranty. www.iLevel.com 1.888.iLevel8. TABLE OF CONTENTS. ALL IN ONETM

Windshield wipers are vehicle specific, so it’s important to know the proper size before purchasing new wipers for your vehicle. Simple measuring or researching online will ensure ...

Description: Design information for TimberStrand LSL, Microllam LVL and Parallam PSL. Document ID #: tj-9000. File Type: pdf. File Size: 3.9 MB. File Date: April 2024. Document Types: Design & Specification. Design information for TimberStrand LSL, Microllam LVL and Parallam PSL.Description: Featuring Trus Joist® TJI® Joists for Floor and Roof Applications. Document ID #: tj-4000. File Type: pdf. File Size: 5.1 MB. File Date: October 2023. Document Types: Design & Specification Categories. Engineered Lumber; Products. TJI® JoistsTJI® joists, it offers the ultimate high performance floor. Benefits of Trus Joist® Rim Board • Longer lengths for faster installation and fewer joints • Depths are sized to match TJI® joists—less cutting and material waste when used together • High vertical load transfer capacity available Sizes Rim material depthFind the perfect TV for your bedroom with this guide. Explore the various screen size options and learn how to get the most out of your TV. By clicking "TRY IT", I agree to receive...Um gajo que não é rapper, não é streamer, não é gamer é o Tji.TJI® joists are sometimes compared to floor trusses as builders make decisions on floor systems. Often, the floor package cost has been the primary, if not only, factor some builders have considered. More recently, that singular focus has been changing. More and more builders are now considering the total business and financial …Jun 13, 2013 · 3 ½” 1.55E TimberStrand ® LSL. 9.5″ to 16″. 5 ¼” 2.0E Parallam ® PSL. 9.5″ to 18″. As you see there are a possible 6 different thicknesses to choose from. The two primary reasons for the difference are load capacity and sufficient width on the edge to accommodate nailing from shear walls and the floor diaphragm above.TB-105 Elevated Garage Floors with Weyerhaeuser Structural Composite Lumber. TB-108 Designing Indoor Pools. TB-112 Moisture Effects on Weyerhaeuser Engineered Wood Products. TB-120 Engineer’s Seal Requirements for I …

Rockville pollen count.

12 inch paper mache numbers.

TJI joists are engineered joists that resist twisting, shrinkage, and warping, and can span longer distances than dimensional lumber. Learn about the different sizes, uses, and …Weyerhaeuser TJI® Joist Floor Framing includes a series of joists made in Canada: Weyerhaeuser Trus Joist® TJI® s31, s33 and s47 joists. These new joists offer a wide nailing surface for faster installation and easier handling, and provide the same guaranteed performance you've come to expect from Weyerhaeuser products.“Knockouts” found in Weyerhaeuser TJI I-Joists are quick and convenient 1 1/2” round holes spaced 12” on center. They are perforated in to the TJI and easil...See page 20 for information on web stiffener sizes and nailing. EXAMPLE: Determine the stiffened end reaction capacity for a 14" PWI 32S with 2" of bearing for a non-snow roof load and supported on an SPF wall plate (425 psi). 1. Determine End Reaction (ER) w/Stiffeners:I Joist Span Comparison Depth Manufacturer Series Flange Size 12" 16" 19.2" 24" 12" 16" 19.2" 24" 9 1/2" Louisiana Pacific LPI 18 1 1/2" X 2 1/2" 16'-6" 15'-1" 14'-3" 13'-4" 18'-3" 16'-8" 15'-3" 13'-7"Feb 12, 2014 · The increased allowable reaction of a TJI joist with web stiffeners assumes (3) nails as shown in detail “W” (figure to left). In some cases higher allowable reactions can be achieved using more nails. Contact your local Trus Joist representative for assistance with higher reaction capacity needs. Web stiffeners can be OSB, plywood or 2x ...Traveling can be a stressful experience, especially when it comes to packing. With the ever-changing regulations for carry on size, it can be difficult to know what is allowed and ...The increased allowable reaction of a TJI joist with web stiffeners assumes (3) nails as shown in detail “W” (figure to left). In some cases higher allowable reactions can be achieved using more nails. Contact your local Trus Joist representative for assistance with higher reaction capacity needs. Web stiffeners can be OSB, plywood or 2x ...TJI® 210, 230, and 360 rim joist: One 16d (0.135" x 31⁄2") nail into each flange. With depths > 16", use TJI® 360 rim joist. TJI® 560 or 560D floor joist. TJI® 560 or 560D rim joist: Toenail with 10d (0.128" x 3") nails, one each side of TJI® joist flange. 13⁄4" minimum bearing.tji–truss joist p/s, timberstrand rim board, versa studs—boise cascade, lsl studs—p/s (special order) Phone (206) 782 3487 2600 N.W. Market St. Seattle, WA 98107Other sizes may be available in Weyerhaeuser software; however, not all products are available in all markets. Contact your Weyerhaeuser representative for the sizes available in your area. This guide features the following Trus Joist® wall framing products: 1.3E TimberStrand ® LSL Studs: 1½" x 3½" (2x4) • 1½" x 5½" (2x6)TJI® joists, it offers the ultimate high performance floor. Benefits of Trus Joist® Rim Board • Longer lengths for faster installation and fewer joints • Depths are sized to match TJI® joists—less cutting and material waste when used together • High vertical load transfer capacity available Sizes Rim material depth ….

Finding the perfect plus size clothing for any occasion can be a challenge. With so many different styles, sizes, and fabrics available, it can be difficult to know what to look fo...Software Solutions. Whether you are a design professional or lumber dealer, Weyerhaeuser offers an array of proprietary software to help you specify individual framing members, create cut lists, manage inventories—even help you design a complete structural frame. Learn more about our software. Technical Support.BCI®Joists are specially constructed I-joists with flanges made from strong VERSA-LAM® laminated veneer lumber with oriented strand board web and approved ...Installation Guide for Floor and Roof Framing with TJI 110, 210, 230, 360 and 560 Joists - tj-9001 ... File Size: 1.6 MB. File Date: September 2023. Document Types ...1. Click on the "Select Image" button to select an image. 2. Enter a new target size for your image. 3. Click the "Resize Image" button to resize the image. Image Resizer. Quickly resize image files online at the highest image quality. No software to install and easy to use.TJI® 210 joists: 3/4˝ x 25/16˝ minimum. TJI® 230 and 360 joists: 7/8˝ x 25/16˝ minimum. Web Stiffener Attachment for TJI® Joists Tight Gap: 1/8˝ minimum 23/4˝ maximum Three 16d (31/2˝) box nails Tight 2x4 web stiffener (2) Filler and Backer Block sizes Typical THF backer block installation Typical THO backer block installation TJI ...Trus Joist® Beam, Header and Column Specier's Guide TJ-9000 | April 2021 26 ALLOWABLE HOLES BEARING LENGTH REQUIREMENTS Reaction (lbs) 1.3E TimberStrand ® LSL 1.55E TimberStrand LSLLegacy TJI®/Pro™ 100TS, 120TS, 130, 150, 250, 350, 550 Literature (1999-2003) Follow The literature below is for legacy Trus Joist ® products only and is not intended for use in current specification.The Attachment at the Bottom is a PDF of the Vertical Structure Depths for Common Imperial Lumber sizes and LVL / TJI sizes at different Roof Pitches. which I made recently with Forum Member "Chopsaw's" help ( Thanks - 'cos Trig. ain't my thing ! ). ( VSD is VRD in older versions of Chief ) VSD as defined in the Reference Manual :Jeff Jenkins tells us about his travel experiences and how he is trying to change the narrative of travel for plus-size travelers through his blog Chubby Diaries. I was compared to... Tji sizes, strength, stiffness and size than traditional lumber, providing a strong, sturdy floor. We offer longer lengths so that ceilings and floors can be designed with fewer pieces, saving time on installation. Other advantages over lumber include lower moisture content, which makes our I-Joists less likely to split, shrink, twist, warp or bow., 9-1/2 in. Pro 230. Add for Pickup Add for Delivery. Product Details. Pro 560 Flange Width: 3-1/2 in.. wide, Flange Thickness: 1-3/8 in. thick, Web thickness: 7/16 in. Easily drilled and cut for plumbing and ductwork. Long lengths allow for versatile floor plans. Ease of installation helps reduce callbacks., I-joists are strong, lightweight, "I" shaped engineered wood structural members that meet demanding performance standards. I-joists are comprised of top and bottom flanges, which resist bending, united with webs, which provide outstanding shear resistance. The flange material is typically laminated veneer lumber (LVL) or solid sawn lumber, and ..., Legacy Trus Joist Commercial Joists TJI® L65, L90, H90 & HS90 Literature (2007) Legacy TJI® 110, 210, 230, 360, 560 Literature (2003-2008) Legacy TJI®/Pro™ 100TS, 120TS, 130, 150, 250, 350, 550 Literature (1999-2003) Legacy Willamette® SJ15, SJ25, SJ35 Literature (1998) Legacy Trus Joist® TJI 15, 25, 35, 35X, 55 DF SP Literature (1985-1997), Document Library. Search for a document and use filters on the left to narrow by product or document type. Go to My Account to access your custom collections of documents and …, 1.Using Table A, Table B, or both if required, determine the hole shape/size and select the TJI® joist and depth. 2. Scan horizontally until you intersect the correct hole size column. 3. Measurement shown is minimum distance from edge of hole to support. 4. Maintain the required minimum distance from the end and the intermediate or cantilever ..., strength, stiffness and size than traditional lumber, providing a strong, sturdy floor. We offer longer lengths so that ceilings and floors can be designed with fewer pieces, saving time on installation. Other advantages over lumber include lower moisture content, which makes our I-Joists less likely to split, shrink, twist, warp or bow., TJI I-Joists. When you choose Trus Joist, you're choosing the brand that: -Invented the very first I-Joist over 50 years ago. -Lead innovation and design to create a suite of Engineered Wood Products, including I-Joist, LVL Microllam, LSL Timberstrand, and PSL Parallam. -Pushed the limits of span charts to make the open floor concepts of today ..., The flanges must remain straight within a. to the first 4 feet of joists at the end of the bay. tolerance of 1/2" from true alignment. Floor Span Tables 5. Trus Joist • TJI® Joist Specifier’s Guide 2026 • April 2003. How to Use These Tables 4. Scan down the column until you meet or exceed the span of your., TJI® joists are sometimes compared to floor trusses as builders make decisions on floor systems. Often, the floor package cost has been the primary, if not only, factor some builders have considered. More recently, that singular focus has been changing. More and more builders are now considering the total business and financial …, The LP® SolidStart® I-joist product line was sold to Pacific Woodtech (PWT) in August of 2022 in connection with our sale of our Engineered Wood Products (EWP) business and SolidStart® brand. For customer support of LP® SolidStart® I-Joists purchased prior to 8/1/2022, contact LP at 1-888-820-0325. For LP® SolidStart® I-Joists purchased ..., The giant retailer is buying Eloquii, a brand focused on stylish plus-size clothing for women, in a bid to expand its fast-growing fashion portfolio. Walmart has just announced its..., TJI 110, 210, 230, 360, & 560 Joists Specifier's Guide - Weyerhaeuser, TJI® Joist Floor Framing TJ-Pro5 Floor Details 656–7 Floor Load Tables 7 Cantilevers 8–9 Roof Span Table 10 Roof Load Tables 10 Roof Framing 11 Roof Details 12–13 Framing Connectors 14–15 deep depth TJi® Joist Sizes As a complement to our standard size TJI® joist series, Weyerhaeuser offers deeper depth joists in the following sizes:, Find the perfect TV for your bedroom with this guide. Explore the various screen size options and learn how to get the most out of your TV. By clicking "TRY IT", I agree to receive..., Continuing on to part 2 of the floor system build, we roll the joists, set the rim board, and firm everything up with metal connectors., TJI®210 joists. 3⁄8" 9½" 117⁄8" 14" 16" 1¼"–13⁄8" 1. ®All blocking, hangers, rim boards, and rim joists at the end supports of the TJI joists must be completely installed and properly nailed. 2. Lateral strength, like a braced end wall or an existing deck, must be established at the ends of the bay., SB For TJI® joists with slopes of 10/12 to 12/12, the vertical depth at bearing will require 11⁄4" TimberStrand® LSL or iLevel® 11⁄8" rim board (for shear blocking) that is one size deeper than the TJI® joist Filler and Backer Block Sizes Product Storage TJI® 110 210 230 or 360 560 Protect products from sun and water Depth CAUTION:, TJ-Pro™ Rating. For more than 50 years, builders have looked to the Trus Joist® name for guidance on floor performance. Our decades of proven success with TJ-Pro™ Rating is one of the biggest reasons why. Builders use TJ-Pro Rating to: Design Floors their customers expect. Manage performance through purchase decisions., Minimizing thermal bridges. The slim double-T shape of the I-joist combines maximum load-bearing capacity with low material usage. This significantly reduces thermal bridges. At the same time, the slim shape allows the amount of insulation to be increased. The use of I-joists can improve the U-value of a building component by up to 15%., Deflections are almost always the governing criteria in determining joist sizes in residential and even commercial applications. First you’ll need to download the most current Trus Joist TJI Manual. The design manual contains all the span tables for different sizes and orientations of joists. The manual also includes span tables based on ..., Articles in this section. Legacy Trus Joist Commercial Joists TJI® L65, L90, H90 & HS90 Literature (2007) Legacy TJI® 110, 210, 230, 360, 560 Literature (2003-2008), Trus Joist® Floor Framing Made Simple. TJI® Joists have a unique shape which can sometimes require special detailing for hangers, bearings, and double joists. Knowing certain constructions details is important to make the floor structurally sound and squeak free. Below are some literature links for framing details., Rim to TJI® Joist TJI® Type # of Nails Size End Int. TJI® 560 or 1¼" or 1½" Top View 560D floor joist 360 All 7⁄8" x 25⁄16"(1) 8d (0.113" x 2½") 3 3 TimberStrand® LSL rim board: TJI® 560 or One 10d (0.131" x 3") nail 560D rim joist: 560 All 2x4(2) 16d (0.135" x 3½") 3 3 into each flange Toenail with 10d, applicable, set forth allowable sizes and location of round, square and rectangular holes in the webs of TJI joists. Duration of Load: ... TJI Joist Series . Flange Size, Depth x Width (inches) Web Thickness (inches) Range of Joist Depths (inches) TJI® 110 : 1.375 x 1.75 . 3/8 : 9½ x 14 . TJI® 210 : 1.375 x 2.08 . 3/8 :, Refer to the hole chart on page 9 of the TJI® Specifiers Guide for uniformly loaded joists. Often, hole size can be increased and holes can be placed closer to bearing than shown on the chart based on actual design spans and loads. Use Forte®WEB single member sizing software to check hole sizes and locations or contact Weyerhaeuser Technical ..., This guide features TJI® joists in the following sizes: Depths: 9½", 117⁄8", 14", 16", 18", 20", 22", and 24" Flange Widths: 1¾", 21⁄16", 25⁄16", and 3½" Flange height and thickness vary by series; see the appropriate sections of this guide for specific sizes and relevant technical information:, 4", use 0.75 of the TJI® Joist header load. Top Flange Hangers: Use 10dx11⁄ 2” nails for all Top Flange hangers attached to an TJI® Joist header. See table for allowable loads. 1. See current Wood Construction Connectors catalog for Important Information and General Notes section and for hanger models, joist sizes,, I-joists are strong, lightweight, "I" shaped engineered wood structural members that meet demanding performance standards. I-joists are comprised of top and bottom flanges, which resist bending, united with webs, which provide outstanding shear resistance. The flange material is typically laminated veneer lumber (LVL) or solid sawn lumber, and ..., The flanges must remain straight within a. to the first 4 feet of joists at the end of the bay. tolerance of 1/2" from true alignment. Floor Span Tables 5. Trus Joist • TJI® Joist Specifier’s Guide 2026 • April 2003. How to Use These Tables 4. Scan down the column until you meet or exceed the span of your., This guide features TJi® joists in the following sizes: Flange Widths: 1¾", 21⁄16", 25⁄16", and 3½" depths: 9½", 117⁄8", 14", and 16" For deeper depth TJi® joists, see the …, Oct 20, 2021 ... Rendered visual of detail H2 in double ply TJI joists., The TJI 110 offers a suitable alternative to 2×10 and 2×12 dimensional lumber. The TJI 220 is larger at 2-1/16” in width. It is identical to the TJI 230 in terms of depth availability. But the TJI 230 is 2-5/16” in width. The TJI 360 and TJI 560 have three depth options and a width of 2-5/16” and 3-1/2”, respectively.