What breakers are compatible with eaton panel

Eaton's mission is to improve the quality of life and the environment through the use of power management technologies and services. We provide sustainable solutions that help our customers effectively manage electrical, hydraulic and mechanical power - more safely, more efficiently and more reliably.

What breakers are compatible with eaton panel. Eaton breakers are generally compatible with Eaton panels. Eaton is a reputable brand that produces both electrical panels and circuit breakers, which are designed to work seamlessly together. When using Eaton breakers, it is crucial to select ones that match the specific model and specifications of the corresponding Eaton panel.

GE: GE (General Electric) breakers are widely used and compatible with various Westinghouse panel models. GE breakers are known for their reliability and durability, ensuring long-lasting protection for your electrical system. They offer different types of breakers, including standard and high-quality circuit breakers.

Compatibility Chart. There are charts that show what circuit breakers are interchangeable. For instance, the chart below shows an example of a cross reference of Type CL 1″ breakers that could be interchangeable for panel installations. You can check under the panel column for compatible Eaton UL Classified breakers.Highlights. Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit) Amperage - (2) 15 Amp. Duplex 1 in. wide breaker. Trips to center position - must turn off then turn back on. For use in type BR load centers. Interrupt rating - 10 kAIC. Voltage rating is 120.Electrical and Industrial | Power management solutions | EatonTLDR: For full-size breakers, use Eaton "CL" (CLassified) type - authorized by UL. For double-stuff breakers, use Eaton's BRD which are marked "Type A" - authorized by your panel labeling. Replace Square-D, green handle BR, and "no-name" tandem/quad breakers. Dangerous old breakers. Wow, you really do have a "breaker museum" in there.However, the Cutler-Hammer is owned by Eaton, so both the Cutler and Eaton breakers are highly compatible with this panel. As mentioned earlier, both Eaton and Cutler breakers are compatible with each other’s electric panel as the manufacturer for both the Company is the same. Also, Westinghouse, Square D is owned by the same owner as cutler ...

Eaton Type BR circuit breaker surge protective device. Catalog Number. BRNSURGECS. UPC. 786689353704. Product Length/Depth. 2.657 in. Product Height. 2.9 in. ... more safely, more efficiently, and more reliably. Eaton's 2020 revenues were $17.9 billion, and we sell products to customers in more than 175 countries. Company. About us; Careers ...EATON www .eaton .com Table 3. PRL1a, PRL2a vertical breaker assemblies Device type a Device mounting Three-phase Single-phase Tin-plated aluminum connector Silver-plated copper connector Tin-plated aluminum connector Silver-plated copper connector Catalog number F-Frame b (100 A maximum) Top fed KB13AFT KB13SFT KB11AFT KB11SFTEaton Type CCV Tenant Main Circuit Breaker,Tenant main circuit breaker,200 A,25 kAIC,Two-pole,120/240 V,#2/0 AWG-300 kcmil Cu/Al,CCV,Type ECC unit enclosures ... Eaton is an intelligent power management company dedicated to improving the quality of life and protecting the environment for people everywhere. We are guided by our commitment to do ...Eaton's enclosed breakers offer all the advantages of circuit breakers packed in an enclosure for 240 Vac applications and include ... The CMBE24L200BTS is a main lug only panel, therefore a bolt on main breaker won't fit. The only way to get a main breaker is to back feed a CH branch breaker. If you have more questions or concerns, please call ...The most common breaker brands compatible with Midwest panels include: 1. Eaton Breakers. Eaton breakers are widely recognized for their quality and compatibility with Midwest panels. They offer a wide range of breakers, including both standard and specialized options. ... If you are unsure about which breaker is compatible with your Midwest ...

EATON www .eaton .com Table 3. PRL1a, PRL2a vertical breaker assemblies Device type a Device mounting Three-phase Single-phase Tin-plated aluminum connector Silver-plated copper connector Tin-plated aluminum connector Silver-plated copper connector Catalog number F-Frame b (100 A maximum) Top fed KB13AFT KB13SFT KB11AFT KB11SFTThe Eaton BR breakers are the replacement for those breakers. The Eaton CL breakers are a classified replacement for the Murray MP line. General Switch panels are ok in my option, but never use General Switch breakers. Those breakers (which I do not see any in your panel thank goodness) would trip once and never reset.Location. San Francisco Bay Area, CA, USA. Occupation. Electrical Engineer. May 21, 2023. #8. The concept of “interchangeability” ended in I think 1990 or so, due to fires that happened when breakers didn’t seat correctly, and the breaker manufacturers blamed the panel manufacturers and vice versa.Listed are breakers documented in documentation with the panel, Classified are substitute breakers by other manufacturers that have been tested for use in the panels indicated in their documentation. Most manufacturers of breakers don't participate in the Classified process, the exception is Eaton.

Doublelist fayetteville.

SPAN is compatible with industry standard 1-inch breakers, both single and 2 pole, including Eaton, Siemens, and Square D, including tandem, quad, AFCI, GFCI styles. A complete list of our compatible breakers can be accessed by SPAN-Authorized installers in our Tech Portal under our Panel Installation Guide (Appendix section).If it's an Eaton BR panel, it takes Eaton or BR breakers. look for local electrical supply houses or order online. Panels usually list all of their accepted breakers on a sticker inside of it or on the cover, but you're basically just going to see what the other posters suggested. I.e. BR or bust.Eaton's residential meter breakers are service entrance equipment systems that consist of a single meter socket and load center or a meter socket and main breaker combined in one enclosure. This design provides the contractor with labor and material savings. The meter breakers are constructed to meet the latest NEC wire bending space requirements.Electrical and Industrial | Power management solutions | EatonAt one time Bryant was the brand of Westinghouse's loadcenter line, then they put the Westinghouse brand on them until they bought the CBS TV network & sold all their industrial lines, Eaton bought the Westinghouse electrical distribution line, put their Cutler-Hammer brand on it until branding everything as Eaton, making everything as …

Sep 1, 2023 · Eaton has UL Classified breakers which are legal and safe to use as replacements for certain other brands of breakers. From the Eaton catalog, page 103, we have: Type CL Replacement Breakers for Square D HOMELINE, General Electric, Crouse-Hinds, Thomas & Betts, Murray and ITE®/Siemens Loadcenters. 20 #14–4 CL120 CL220. So the CL220 is a ...Electrical and Industrial | Power management solutions | EatonIf main tenant breakers are installed in Eaton's modular metering stack, branch breakers installed in a downstream panel rated 10 kAIC or greater are protected to the listed series AIC rating. Any additional or replacement branch breakers must be of the same manufacture and type, and their interrupting current rating must be equal to or greaterEATON www .eaton .com Table 3. PRL1a, PRL2a vertical breaker assemblies Device type a Device mounting Three-phase Single-phase Tin-plated aluminum connector Silver-plated copper connector Tin-plated aluminum connector Silver-plated copper connector Catalog number F-Frame b (100 A maximum) Top fed KB13AFT KB13SFT KB11AFT KB11SFTEaton Type BR breakers are also listed as Type C, so they are completely compatible with your panel's labeling. It's also a modern, fully-supported breaker line, so you can easily get AFCI, GFCI, and other newer breaker types as needed. A basic Type BR/Type C 20 A breaker looks like this : Original Challenger Breakers Are A Problem. I …EATON CORPORATION Cable-in / cable-out circuit breakers and protectors 1 Cable-in / cable-out miniature circuit breakers and supplementary protectors Eaton offers a complete line of circuit breakers with its WMZT and QC product lines engineered for branch circuit protection and its WMZS product line designed for supplementary protection.4. Residential Circuit Breakers. Eaton compatible breakers used in a residential setting can be practical options for different applications. For instance, installers can use these models in an Eaton panel as arc fault circuit interrupters (AFCI) or ground fault circuit interrupters (GFCI).. Related: A Comparison Between AFCI vs GFCI. Eaton's AFCIs function by protecting electronic devices ...What breakers are compatible with GE panel? Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. If the wrong breaker is used it could fail to break (shut off power) during a surge.Find an authorized distributor or sales rep near you. Email us using the link above, or call our Customer Support team at 1-866-764-5454. Explore other Eaton solutions. Crouse-Hinds series FLB explosionproof circuit breakers are used for service entrance, feeder or branch circuit protection for lighting, heating, appliance and motor circuits.Unsurprisingly, the Federal Pacific Electric Company has since gone out of business. For this reason, the only reliable Federal Pacific breaker cross reference I can recommend is the list that Connecticut Electric has provided, which I've linked to. They are the only Federal Pacific breakers compatible with today's safety standards and are ...The Challenger Circuit Breaker Replacement Chart is an essential tool for anyone who owns a Challenger brand load center. Challenger Half size Type A Circuit Breaker. The Challenger Electric Type A circuit breaker is a half-inch thick, 10,000 kAIC 15 to 30 amp right side and left clip type for use in load centers such as the Challenger or T&B ...Panelboard Interior, 225 Amp, 208Y/120V AC, 4-Wire, 3-Phase, 10 kAIC, 42-Space, 42-Circuit, Copper Bus, Breaker Type: BAB. Main Breaker/Lug Provision on the Top of the Interior. ***For use with 48" Can & Trim***, Cat #: PRL1A3225X42CS, Mfr: Eaton ... Panel Board, Interior, PRL1A, 225A, 120/208V, 42 Circuits ... Eaton's assembled panelboards ...

May 19, 2023 · Yes, some Eaton breakers can be compatible with Murray. Eaton’s UL-rated breakers are designed and proven to be mechanically and electrically interchangeable with circuit breakers from General Electric, ITE/Siemens, Thomas & Betts, Crouse-Hinds, Murray, and Square D. Conclusion. The Murray products will no longer be manufactured. So, finding ...

May 19, 2023 · Ensuring the component’s compatibility in electric systems is important, especially the circuit breaker. The popular names satisfying Crouse Hinds compatible breakers are Siemens and Eaton. Before replacing the old breaker, ensure measurements and metrics are fine—for example, voltage, amperage rating, dimensions, etc.Eaton is a registered trademark. All other trademarks are property of their respective owners. Eaton. 1000 Eaton Boulevard Cleveland, OH 44122 United StatesOct 1, 2023 · The Westinghouse circuit breakers cross reference is a list of exact models of your breaker brand. If you are having a hard time finding your exact breaker model in the market, you can find another brand. As said earlier, Westinghouse circuit breakers are compatible with Square D, Eaton, and Cutler-Hammer because they have the same ownership.Eaton is also a specialist in making UL-Classified breakers for competitor panels; these require a tortuous UL-approval process to prove compatibility with the shape of the bus stabs on competitor panels, and Cutler Hammer mastered that to the satisfaction of UL, with their CL line, which is listed for several competitor panels.Circuit breakers. Eaton's smart circuit breaker is a revolutionary miniature circuit breaker built with Wi-Fi functionality to allow remote monitoring and control of a branch circuit. This functionality allows Eaton to support numerous applications from the utility to the business owner to the homeowner as an integrated part of the system.Nov 16, 2021 ... What's good everyone for this episode we switch out a breaker on a Cutler - Hammer Panel. It's a 277/480V panel. Questions and comments are ...In addition to Siemens and Eaton circuit breakers, there are several other brands that offer compatible breakers for a Challenger panel. These include GE, Square D, Bryant, Cutler-Hammer and Westinghouse. Additionally, some of these companies may also manufacture their own line of Challenger-compatible breakers.Primary application. • Main breakers inside 125 A residential meter stacks. • Primary disconnect for a main lug-only loadcenter in individual apartments in multifamily dwelling. Secondary application. • Main breaker in 100 and 125 A loadcenters. • Sub-feed a 100 A panel or for other 100 A loads. Catalog Nos. CCV2200 and CV3200.

Comcast down in minneapolis.

Volunteer auto group sweetwater tn.

If you have certain electrical box from this brand, it be right to know what breakers what compatible with GE panels. This way, ... For example, the following Eaton Cutler-Hammer Series breakers are interchangeable with that following GE breakers: Amp Rating: Dining Cutler-Hammer Batch.We also provided a list of common breaker brands that are known to be compatible with Westinghouse panels, including Eaton Cutler-Hammer, Siemens, Square D by Schneider Electric, GE, and Murray. These brands offer a range of breakers that have been designed and tested to work seamlessly with Westinghouse panels.Feb 13, 2013 ... Two types of Cutler Hammer Breakers. Tan handle or black Know the difference. Thanks for watching! - David [email protected] Follow me ...TLDR: For full-size breakers, use Eaton "CL" (CLassified) type - authorized by UL. For double-stuff breakers, use Eaton's BRD which are marked "Type A" - authorized …Therefore, you can use any breaker that is UL certified than an acceptable replacement to Mercedes, as listed on your panel box. Eaton is the most commonly adequate and readily available replacement. Breakers Compatible at Siemens Murray QUF, QPF, QT, and QP Siemens breakers. UL-certified Eatons switch. What Breakers …CH and BR Breaker Compatibility Chart. To answer the first question of whether CH breakers are interchangeable with BR breakers, the short answer is no. Eaton designed separate load centers or electrical panels for either one. These are the breaker brands you can interchange with BR and CH breakers:Posts: 1,499. Upvotes: 33. Received 92 Upvotes on 84 Posts. What do you mean "new Westinghouse Bryant" as those two sold out long ago and are now the current Eaton (was Cutler-Hammer). A new Eaton BD1520 should be the correct breaker. Double check the label in the panel to see the breaker types accepted. Upvote.Listed are breakers documented in documentation with the panel, Classified are substitute breakers by other manufacturers that have been tested for use in the panels indicated in their documentation. Most manufacturers of breakers don't participate in the Classified process, the exception is Eaton. ….

I'm focusing today on Siemens breaker and Square D Homeline panel compatibility. In general, the Square D Homeline panel is compatible with most of the main circuit breaker brands in the market. You can use Siemens, GE, Westinghouse, Eaton, and Murray breakers with Square D Homeline panels. When you use Siemens, use QP or QT series breakers.Circuit breakers. Eaton's smart circuit breaker is a revolutionary miniature circuit breaker built with Wi-Fi functionality to allow remote monitoring and control of a branch circuit. This functionality allows Eaton to support numerous applications from the utility to the business owner to the homeowner as an integrated part of the system.GE breakers will work in Cutler-Hammer panels, but you will need to use an adapter because they don't fit. The most popular adapter is the GE GHB breakers. Eaton Breakers with Cutler-Hammer. Eaton breakers are almost all compatible with Cutler-Hammer panels. Eaton owns Cutler-Hammer, so they make sure their products are interchangeable.Square D Homeline breakers are designed for use in Square D Homeline panels only. The rating label on the panel or instruction manual will tell you what type of breakers are compatible with it, as well as the maximum amperage each breaker can handle. Additionally, the CP rating on each breaker indicates its current-handling capacity and should ...Eaton Molded Case Breakers in Assemblies Breaker Range Breaker Type KAIC @ 240Vac KAIC @ 277Vac KAIC @ 347Vac KAIC @ 600Vac Terminals 15A to 225A ED 2-P 200A ... CDP Copper Panel (1976 to Late 1990) Catalogue No. Description 1916B93G04 FOR 2 EB / FB / HFB BREAKERS - 150A max breaker.Reading of this document from Eaton breakers bearing the Eaton brand are compatible with the older Challenger (and Cutler-Hammer, Westinghouse and Bryant) branded panels. Eaton Type BR breakers normally bear the Type A or C marking also. BR's are usually a bit cheaper and more readily available.The ITE circuit breaker company remains a prestigious name in the circuit breaker manufacturing world. Today, Siemens continues to sell many lines of circuit breakers under the ITE name. Replacing ITE breakers is easy and also can be used as replacement parts to recondition existing ITE breakers.|The ITE circuit breaker company remains a …All type CH product warranties are rendered null and void if a breaker other than those specifically listed by UL for use in the type CH product is installed. EATON WARRANTY DEPARTMENT 1725 1200THAVENUE LINCOLN, IL 62656. 2 EATON Type CH Loadcenters and Meterbreakers Warranty WA00301001Y Effective: August 2005.Similarly, you will see that Eaton's CL line of breakers is not UL-classified for use in Eaton BR panels-- even though the breakers may look outwardly the same. This should not be confused with cross-listing. For instance, Challenger panels have breakers known to be defective (but panels are fine). People seeking to replace those breakers find ... What breakers are compatible with eaton panel, Eaton Breaker Compatibility Chart - Canada. CEC . Jump to Latest Follow 5K views 8 replies 7 participants last post by 99cents May 9, 2019. Max C. Discussion starter 554 posts · Joined 2016 Add to quote; Only show this user #1 · May 8, 2019. Does anybody know where to find Eaton's current breaker compatibility chart for their molded-case ..., Highlights. Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit) Amperage - (2) 20 Amp. 1 in. plug-on circuit breaker. Trips to center position - must turn off then turn back on. For use in type BR load centers. Interrupt rating - 10 kAIC. Voltage rating is 120/240-Volt., With Brand C breakers, you can have peace of mind knowing that your electrical system is protected. 4. Brand D Breaker: Brand D is also known for producing compatible breakers for Stab-Lok panels. These breakers are engineered to fit securely and provide reliable protection against overloads and short circuits., GE breakers will work in Cutler-Hammer panels, but you will need to use an adapter because they don't fit. The most popular adapter is the GE GHB breakers. Eaton Breakers with Cutler-Hammer. Eaton breakers are almost all compatible with Cutler-Hammer panels. Eaton owns Cutler-Hammer, so they make sure their products are interchangeable., Siemens. Most compatibility charts you consult will classify Eaton and Siemens as swappable breakers. If you have doubts, remember that Eaton is compatible with Cutler Hammer. Cutler Hammer is interchangeable with Murray. This matters because Siemens and Murray are basically the same company., Dec 5, 2022 ... ... work being completed by, a qualified professional. Codes and Regulations for possible work included within the video may of may not differ ..., Eaton, Occupation. Electrical Engineer. Mar 10, 2023. #7. "CL" is the Eaton breaker series number, not a "listing" like UL. Eaton makes two breakers that appear to be identical; the BR series and the CL series. The BR series are ONLY listed to be used in Eaton BR series panels and their predecessor, Bryant /Westinghouse panels., Ensuring the component's compatibility in electric systems is important, especially the circuit breaker. The popular names satisfying Crouse Hinds compatible breakers are Siemens and Eaton. Before replacing the old breaker, ensure measurements and metrics are fine—for example, voltage, amperage rating, dimensions, etc., Cutler-Hammer products are now under the Eaton brand of equipment. Learn how to order Cutler-Hammer parts, including Cutler-Hammer breakers. Cutler-Hammer breakers are available on..., Jan 9, 2017 · 5,076 34 105 139. Post a photograph of some of the breakers and any markings on them. There have been a lot of mergers and acquisitions in the business, so some companies (e.g. Eaton or Square D) have several incompatible product lines. Have to watch for that. Siemens still uses the Murray brand so if the panel doesn't say Murray I would stick ..., Eaton Breaker Compatibility Chart - Canada. CEC . Jump to Latest Follow 5K views 8 replies 7 participants last post by 99cents May 9, 2019. Max C. Discussion starter 554 posts · Joined 2016 Add to quote; Only show this user #1 · May 8, 2019. Does anybody know where to find Eaton's current breaker compatibility chart for their molded-case ..., BAB3045H. Approval UL, CSA. CE. 3 Pole 45A Thermal Magnetic circuit breaker, Miniature bolt on breaker are mainly used in commercial to light industrial application. These breakers guarantee direct power feed and energy efficient. Cost is double that of plug in breakers, but bolt ons last much longer and exceed the power factor demand of plug ins., In that case, I highly make lookup for one GE circuit breaker compatibility chart online at see the compatible replacement for your unit. Molded cases circuit breakers aftermarket answers Also, you can call a professional electrician and ask any brand also type of breaker is interchangeable with your GE unit., Designed to fit virtually any panel Eaton's UL classified breakers are designed and tested to be both mechanically and electrically interchangeable with circuit breakers manufactured by General Electric, Thomas & Betts, ITE/Siemens, Murray, Crouse-Hinds, and Square D. ... As said earlier, Westinghouse circuit breakers are compatible with ..., BRP30B100. Eaton BR main breaker loadcenter, Plug-on neutral main circuit breaker loadcenter, 100 A, X5, Aluminum, Cover included, NEMA 1, Metallic, 10 kAIC, BR, 60 circuits, Single pole, 30 spaces, Two hots, a neutral and a ground, Single-phase. Contact me. Load center fundamentals. Loadcenters and circuit breakers catalog., Eaton provides a comprehensive product offering to protect your home electronics against surge events. Two stages of surge suppression are recommended to provide the best protection for electronic equipment. Two-stage surge suppression should be installed at the service entrance and point of use. Many of our Type II surge devices are UL 1449 ..., The buses are still the same to maintain backwards compatibility and because the original bus is perfectly fine. You must change every breaker in the panel to BR type. Since the Challenger breakers are dangerous, every breaker in your panel needs to be a Type BR/Type C from Bryant, Cutler Hammer or Eaton. If it's not, change it now., Eaton is a registered trademark. All other trademarks are property of their respective owners. Eaton. 1000 Eaton Boulevard Cleveland, OH 44122 United States, The Eaton Cutler-Hammer 125 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short circuit. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt., Siemens breakers in an Eaton panel. Thread starter Jy man; Start date Oct 28, 2022; Status Not open for further replies. J. Jy man ... is there a compatibility issue using Siemens knife blade brkrs in an Eaton panel…can't find anything on line? 100a pn, used single pole 15 and a single pole 20 (12 gauge wire) ..., equivalent of Eaton’s Cutler-Hammer Series Smart Breaker™ however, our devices have been UL Classified to be installed in their panels, and you can offer the benefits of Smart Breaker™ to your customers regardless of their installed base. 1-Pole 120/240 VAC 10,000 AIC 2-Pole 120/240 VAC 10,000 AIC 1-Pole 120 VAC 10,000 AIC GFCI 1-Pole ..., Electrical and Industrial | Power management solutions | Eaton, HP404040SHL. Eaton Cutler-Hammer series Housing panel, 400A, 120/240V, BRH/BWH Secondary Ciruit, Aluminum Bus Material, Lever bypass, NEMA 3R Enclosure, Underground Feed Type, 22 kAIC Interrupt Rating, Surface mounting, Ringless Security, 1 Socket. Contact me. Metering selector tool. Metering products catalog., Eaton Smart Breakers are an industry first-combining protective features you'd expect with the intelligence needed to enable smarter energy decisions. Advanced functionality built into these smart breakers ... The BREM1015 is compatible with Eaton BR load centers. If you need help selecting a BR panel, please call our technical support team at ..., The HO doesn't want to pay for a new panel when the one he has will likely work fine for many more years. Thanks to everyone for the help. I've responded to the RFI, amending the note about matching breakers to what's existing in the panel, to allow other breakers listed as replacements/suitable for use in that panel., Primary application. • Main breakers inside 125 A residential meter stacks. • Primary disconnect for a main lug-only loadcenter in individual apartments in multifamily dwelling. Secondary application. • Main breaker in 100 and 125 A loadcenters. • Sub-feed a 100 A panel or for other 100 A loads. Catalog Nos. CCV2200 and CV3200., Pow-R-Line 1a lighting and appliance panelboards. Eaton's Pow-R-Line 1a lighting panelboards provide a compact and flexible solution for electric power distribution with integrated breakers, metering, and surge protection. In addition, these panelboards are designed to meet UL 67 and NEMA PB1 standards for use in data centers, industrial ..., With Brand C breakers, you can have peace of mind knowing that your electrical system is protected. 4. Brand D Breaker: Brand D is also known for producing compatible breakers for Stab-Lok panels. These breakers are engineered to fit securely and provide reliable protection against overloads and short circuits., 20-20 A. These breakers are only compatible with Eaton's Type CH loadcenters. Design features • Space saving ¾-inch twin design accommodates more breakers per panel • Suitable for all CH CTL and non-CTL loadcenters • Suitable for CH plug-on neutral loadcenters • Two-position handle eliminates the need to reset the breaker Product ..., Get free shipping on qualified Eaton Circuit Breakers products or Buy Online Pick Up in Store today in the Electrical Department. ... Electrical Panels & Protective Devices / Circuit Breakers. Eaton Circuit Breakers. Challenger. ... Universal Series Compatibility. Bulk Assortment. Maximum Amperage. 15 amp. 20 amp. 25 amp. 30 amp. 35 amp. 40 amp ..., Officially, no. You need approved Eaton breakers or a third party that is Listed for use with that specific panel. If you violate that and your house burns down for any reason, your insurance company could deny claims., Eaton